Design and Patient-Level Evaluation of a Web-Based Convolutional Neural Network System for Detecting Malaria Parasites in Thin Blood Smear Cell Images

Light microscopy of Giemsa-stained blood smears is the reference method for diagnosing malaria, yet reading slides is slow and depends on expertise that is scarce where the disease is common. We developed a lightweight convolutional neural network (CNN) that labels segmented red blood cell images as parasitized or uninfected and placed it behind a browser-based decision-support application. The network, with three convolutional blocks and 4.83 million parameters, was evaluated on the public National Library of Medicine collection of 27,558 cell images from 200 individuals using five-fold cross-validation in which every cell from a given individual stayed in the same fold. On the held-out folds, accuracy was 94.4% (95% confidence interval [CI] 93.2–95.5%, patient-level bootstrap), sensitivity 93.4% (91.4–95.0%), specificity 95.4% (93.9–96.7%) and the area under the receiver operating characteristic curve 0.980 (0.974–0.985). Splitting the same images at random, without regard to the individual, raised accuracy to 95.2% and shrank its between-fold standard deviation from 1.35 to 0.26 percentage points, so cell-level evaluation overstated both performance and its stability. Errors were concentrated in a minority of individuals: per-patient accuracy had a median of 97.0% but fell below 90% for 15 of the 200. Model scores were well calibrated (expected calibration error 0.009), and one image was classified in about 22 ms on a standard processor. The application is intended to assist microscopists, not to replace them; validation on independently collected smears and an automated cell-segmentation stage are required before any clinical use.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-26
DOI
https://doi.org/10.21203/rs.3.rs-11527641/v1
Primary Topic
Digital Imaging for Blood Diseases
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Design and Patient-Level Evaluation of a Web-Based Convolutional Neural Network System for Detecting Malaria Parasites in Thin Blood Smear Cell Images

Abdulhakeem Rotimi Agboola, Abdusamea I. A Omer, Item Justin Atangwho, Rabyah B. Ali et al.
Research Square
Digital Imaging for Blood Diseases
preprint

Design and Patient-Level Evaluation of a Web-Based Convolutional Neural Network System for Detecting Malaria Parasites in Thin Blood Smear Cell Images

Abdulhakeem Rotimi Agboola, Abdusamea I. A Omer, Item Justin Atangwho, Rabyah B. Ali, Aisha Lutfi Abdul Latif, Anietie Justin Atangwho, Esraa Mustafa Melid
preprint en

Abstract

Light microscopy of Giemsa-stained blood smears is the reference method for diagnosing malaria, yet reading slides is slow and depends on expertise that is scarce where the disease is common. We developed a lightweight convolutional neural network (CNN) that labels segmented red blood cell images as parasitized or uninfected and placed it behind a browser-based decision-support application. The network, with three convolutional blocks and 4.83 million parameters, was evaluated on the public National Library of Medicine collection of 27,558 cell images from 200 individuals using five-fold cross-validation in which every cell from a given individual stayed in the same fold. On the held-out folds, accuracy was 94.4% (95% confidence interval [CI] 93.2–95.5%, patient-level bootstrap), sensitivity 93.4% (91.4–95.0%), specificity 95.4% (93.9–96.7%) and the area under the receiver operating characteristic curve 0.980 (0.974–0.985). Splitting the same images at random, without regard to the individual, raised accuracy to 95.2% and shrank its between-fold standard deviation from 1.35 to 0.26 percentage points, so cell-level evaluation overstated both performance and its stability. Errors were concentrated in a minority of individuals: per-patient accuracy had a median of 97.0% but fell below 90% for 15 of the 200. Model scores were well calibrated (expected calibration error 0.009), and one image was classified in about 22 ms on a standard processor. The application is intended to assist microscopists, not to replace them; validation on independently collected smears and an automated cell-segmentation stage are required before any clinical use.

Research Square
University of Calabar (NG), Sabratha University (LY), University Of Calabar Teaching Hospital (NG)
Digital Imaging for Blood Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon