Beyond Resonance Metrics: Evidence-Based System Benchmarking of Metasurface Sensors from Transduction to Deployment

Metasurface sensors are commonly compared using resonance sensitivity, quality factor, linewidth, field enhancement, or derived figures of merit. These device-level descriptors do not establish whether the complete measurement chain is calibrated, reproducible, or usable with realistic samples. Six systematic Scopus searches returned 16,592 records. Prioritized screening and deterministic reduction produced the original 217-study purposive panel; a revision audit excluded 21 records without replacement. Within the revised 196-study panel, 151 (77.0%) reached Metasurface Sensor Evidence and Integration Level (MSEIL) 6–7 and 173 (88.3%) used high-complexity readers. Eleven (5.6%) reported independent devices or batches, 24 (12.2%) reported a statistical or noise-defined analytical detection limit, and three (1.5%) demonstrated an end-to-end prototype. In a separate selection sensitivity analysis, removing the MSEIL weight reduced the share at levels 6–7 from 81.4% to 62.3% among 220 reselected records. These frequencies describe the sampled panels and do not estimate prevalence in the field. The review proposes a minimum reporting set for benchmarking sensors within compatible measurement families.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-11-26
DOI
https://doi.org/10.3390/s26237477
Primary Topic
Metamaterials and Metasurfaces Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Beyond Resonance Metrics: Evidence-Based System Benchmarking of Metasurface Sensors from Transduction to Deployment

Jorge Contreras-Martínez, Abdellah Touhafi, Gianluca Cornetta
Sensors
Metamaterials and Metasurfaces Applications
article

Beyond Resonance Metrics: Evidence-Based System Benchmarking of Metasurface Sensors from Transduction to Deployment

Jorge Contreras-Martínez, Abdellah Touhafi, Gianluca Cornetta
article en

Abstract

Metasurface sensors are commonly compared using resonance sensitivity, quality factor, linewidth, field enhancement, or derived figures of merit. These device-level descriptors do not establish whether the complete measurement chain is calibrated, reproducible, or usable with realistic samples. Six systematic Scopus searches returned 16,592 records. Prioritized screening and deterministic reduction produced the original 217-study purposive panel; a revision audit excluded 21 records without replacement. Within the revised 196-study panel, 151 (77.0%) reached Metasurface Sensor Evidence and Integration Level (MSEIL) 6–7 and 173 (88.3%) used high-complexity readers. Eleven (5.6%) reported independent devices or batches, 24 (12.2%) reported a statistical or noise-defined analytical detection limit, and three (1.5%) demonstrated an end-to-end prototype. In a separate selection sensitivity analysis, removing the MSEIL weight reduced the share at levels 6–7 from 81.4% to 62.3% among 220 reselected records. These frequencies describe the sampled panels and do not estimate prevalence in the field. The review proposes a minimum reporting set for benchmarking sensors within compatible measurement families.

SensorsVol. 26(23)
Universidad San Pablo CEU (ES), Universidad Complutense de Madrid (ES), Vrije Universiteit Brussel (BE)
Metamaterials and Metasurfaces Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon