Design and Development of a Wearable Posture Monitoring Prototype Using a Single IMU

Long term use of computers can cause changes in head and neck posture. The project developed a wearable device for monitoring continuous sensor tilt deviation and providing posture reminders. The system uses Arduino UNO R4 and MPU6050, and is connected near C7 using tape and 3D printed casing. Acceleration measurement uses a low-pass filter to estimate the sensor tilt angle. Establish personal reference angles for three calibration records. The program classifies absolute deviations using thresholds of 5°, 10°, and 15°. A deviation of at least 5° for 10 seconds will result in a serial warning and LED feedback. A supporting iOS application has also been developed. For the 5 reference angles, the average absolute error generated by the simulated average estimation is 0.198°, and the maximum absolute error is 0.317°. The sensor measures the local inclination, which is affected by the movement of the torso and changes in attachments. The absolute deviation rule does not distinguish between forward and backward movements. Further testing is needed to evaluate measurement errors, calibration repeatability, warning time, and hardware to application communication.

Authors

Institutions

Publication Details

Journal
Applied Science and Innovative Research
Published
2026-11-26
DOI
https://doi.org/10.22158/asir.v10n4p37
Primary Topic
Ergonomics and Musculoskeletal Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Design and Development of a Wearable Posture Monitoring Prototype Using a Single IMU

LiWei LIU
Applied Science and Innovative Research
Ergonomics and Musculoskeletal Disorders
article

Design and Development of a Wearable Posture Monitoring Prototype Using a Single IMU

LiWei LIU
article en

Abstract

Long term use of computers can cause changes in head and neck posture. The project developed a wearable device for monitoring continuous sensor tilt deviation and providing posture reminders. The system uses Arduino UNO R4 and MPU6050, and is connected near C7 using tape and 3D printed casing. Acceleration measurement uses a low-pass filter to estimate the sensor tilt angle. Establish personal reference angles for three calibration records. The program classifies absolute deviations using thresholds of 5°, 10°, and 15°. A deviation of at least 5° for 10 seconds will result in a serial warning and LED feedback. A supporting iOS application has also been developed. For the 5 reference angles, the average absolute error generated by the simulated average estimation is 0.198°, and the maximum absolute error is 0.317°. The sensor measures the local inclination, which is affected by the movement of the torso and changes in attachments. The absolute deviation rule does not distinguish between forward and backward movements. Further testing is needed to evaluate measurement errors, calibration repeatability, warning time, and hardware to application communication.

Applied Science and Innovative ResearchVol. 10(4)
Northern Arizona University (US)
Ergonomics and Musculoskeletal Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Design and Development of a Wearable Posture Monitoring Prototype Using a Single IMU — LiWei LIU · Applied Science and Innovative Research (2026) | TGRS Research Map | TGRS