Machine-Learning-Enabled Electrochemical Referencing for Blank-Free Electrochemiluminescence Detection
Electrode-to-electrode variability presents a major challenge in electrochemiluminescence (ECL) sensing, often requiring individual blank measurements to distinguish analytedependent responses from variations in baseline emission. We report a machine-learningenabled electrochemical (EC) referencing strategy that estimates electrode-specific blank ECL intensities from current signals recorded simultaneously with ECL emission. The approach was demonstrated using PEDOT-EG4-OMe-modified screen-printed electrodes for mesalazine (5aminosalicylic acid, 5-ASA) through quenching of the Ru(bpy)32+/triethylamine ECL system, representing, to the best of our knowledge, the first ECL-based detection of 5-ASA. The platform exhibited an estimated detection limit of 127 nM in PBS and recoveries of 93.9–108.3% in 500-fold-diluted serum. In spike-in samples prepared using 50-fold-diluted serum from six donors, substantial electrode-to-electrode variation obscured analyte-dependent responses. Using leave-one-donor-out cross-validation, conventional blank-normalized ECL intensity distinguished unspiked serum from serum containing 10 µM 5-ASA with a balanced accuracy of 0.861, whereas raw ECL intensity yielded 0.486. Although additional EC descriptors did not improve direct classification, they contained information associated with electrode-dependent variations. A ridge regression model trained to predict blank ECL intensity from EC descriptors achieved R2= 0.72 for held-out donors. Normalization using the predicted blank yielded a balanced accuracy of 0.833, approaching that obtained using measured blanks, and retained a balanced accuracy of 0.806 without preliminary calibration-based electrode selection. Although lower 5-ASA concentrations could not be reliably distinguished in the higher-content serum matrix, the proposed strategy demonstrates that simultaneously acquired EC signals can provide an internal reference without requiring electrode-specific blank measurements during prediction. This strategy offers a practical route toward simplified ECL sensing with reduced measurement time and reagent consumption, without introducing additional luminophores or hardware.
Authors
- Shyh‐Chyang Luo (ORCID: https://orcid.org/0000-0003-3972-1086)
- Nien-Chieh Tsai
- Clarissa Rouju Tai
- Shu-Chen Wei
- Yun-Xuan Wu
Institutions
- National Taiwan University (TW)
- National Taiwan University Hospital (TW)
Publication Details
- Journal
- ChemRxiv
- Published
- 2026-11-26
- DOI
- https://doi.org/10.26434/chemrxiv.15012851/v1
- Primary Topic
- Electrochemical sensors and biosensors
- Type
- preprint