Machine-Learning-Enabled Electrochemical Referencing for Blank-Free Electrochemiluminescence Detection

Electrode-to-electrode variability presents a major challenge in electrochemiluminescence (ECL) sensing, often requiring individual blank measurements to distinguish analytedependent responses from variations in baseline emission. We report a machine-learningenabled electrochemical (EC) referencing strategy that estimates electrode-specific blank ECL intensities from current signals recorded simultaneously with ECL emission. The approach was demonstrated using PEDOT-EG4-OMe-modified screen-printed electrodes for mesalazine (5aminosalicylic acid, 5-ASA) through quenching of the Ru(bpy)32+/triethylamine ECL system, representing, to the best of our knowledge, the first ECL-based detection of 5-ASA. The platform exhibited an estimated detection limit of 127 nM in PBS and recoveries of 93.9–108.3% in 500-fold-diluted serum. In spike-in samples prepared using 50-fold-diluted serum from six donors, substantial electrode-to-electrode variation obscured analyte-dependent responses. Using leave-one-donor-out cross-validation, conventional blank-normalized ECL intensity distinguished unspiked serum from serum containing 10 µM 5-ASA with a balanced accuracy of 0.861, whereas raw ECL intensity yielded 0.486. Although additional EC descriptors did not improve direct classification, they contained information associated with electrode-dependent variations. A ridge regression model trained to predict blank ECL intensity from EC descriptors achieved R2= 0.72 for held-out donors. Normalization using the predicted blank yielded a balanced accuracy of 0.833, approaching that obtained using measured blanks, and retained a balanced accuracy of 0.806 without preliminary calibration-based electrode selection. Although lower 5-ASA concentrations could not be reliably distinguished in the higher-content serum matrix, the proposed strategy demonstrates that simultaneously acquired EC signals can provide an internal reference without requiring electrode-specific blank measurements during prediction. This strategy offers a practical route toward simplified ECL sensing with reduced measurement time and reagent consumption, without introducing additional luminophores or hardware.

Authors

Institutions

Publication Details

Journal
ChemRxiv
Published
2026-11-26
DOI
https://doi.org/10.26434/chemrxiv.15012851/v1
Primary Topic
Electrochemical sensors and biosensors
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Machine-Learning-Enabled Electrochemical Referencing for Blank-Free Electrochemiluminescence Detection

Shyh‐Chyang Luo, Nien-Chieh Tsai, Clarissa Rouju Tai, Shu-Chen Wei et al.
ChemRxiv
Electrochemical sensors and biosensors
preprint

Machine-Learning-Enabled Electrochemical Referencing for Blank-Free Electrochemiluminescence Detection

Shyh‐Chyang Luo, Nien-Chieh Tsai, Clarissa Rouju Tai, Shu-Chen Wei, Yun-Xuan Wu
preprint en

Abstract

Electrode-to-electrode variability presents a major challenge in electrochemiluminescence (ECL) sensing, often requiring individual blank measurements to distinguish analytedependent responses from variations in baseline emission. We report a machine-learningenabled electrochemical (EC) referencing strategy that estimates electrode-specific blank ECL intensities from current signals recorded simultaneously with ECL emission. The approach was demonstrated using PEDOT-EG4-OMe-modified screen-printed electrodes for mesalazine (5aminosalicylic acid, 5-ASA) through quenching of the Ru(bpy)32+/triethylamine ECL system, representing, to the best of our knowledge, the first ECL-based detection of 5-ASA. The platform exhibited an estimated detection limit of 127 nM in PBS and recoveries of 93.9–108.3% in 500-fold-diluted serum. In spike-in samples prepared using 50-fold-diluted serum from six donors, substantial electrode-to-electrode variation obscured analyte-dependent responses. Using leave-one-donor-out cross-validation, conventional blank-normalized ECL intensity distinguished unspiked serum from serum containing 10 µM 5-ASA with a balanced accuracy of 0.861, whereas raw ECL intensity yielded 0.486. Although additional EC descriptors did not improve direct classification, they contained information associated with electrode-dependent variations. A ridge regression model trained to predict blank ECL intensity from EC descriptors achieved R2= 0.72 for held-out donors. Normalization using the predicted blank yielded a balanced accuracy of 0.833, approaching that obtained using measured blanks, and retained a balanced accuracy of 0.806 without preliminary calibration-based electrode selection. Although lower 5-ASA concentrations could not be reliably distinguished in the higher-content serum matrix, the proposed strategy demonstrates that simultaneously acquired EC signals can provide an internal reference without requiring electrode-specific blank measurements during prediction. This strategy offers a practical route toward simplified ECL sensing with reduced measurement time and reagent consumption, without introducing additional luminophores or hardware.

ChemRxiv
National Taiwan University (TW), National Taiwan University Hospital (TW)
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon