Cross-validation of nanoscale SiO 2 film thickness by ellipsometry and TEM using three distinct physical length references
Accurate measurement of film thickness directly affects product performance in nanomanufacturing, and measurement reliability depends on a rigorous metrological traceability chain. Conventional film thickness measurements by ellipsometry and cross-sectional transmission electron microscopy (TEM) are traceable to the SI through calibration against a certified film thickness standard and the Si(111) lattice-plane spacing, respectively. A third route uses an atom-lithographic self-traceable chromium nanograting whose pitch is linked to the chromium atomic transition frequency. Combining multiple traceability routes can improve the reliability of measurement results. However, the metrological compatibility of results obtained through different traceability routes has not been systematically assessed, and an appropriate method for combining compatible results into a single reference value remains to be established. In this work, a single-layer SiO 2 film with a thickness of approximately 11 nm was measured using ellipsometry calibrated against a film thickness standard, TEM calibrated using the silicon lattice spacing, and TEM calibrated using a self-traceable grating. The consistency among the measurement results was evaluated in terms of metrological compatibility, and a film thickness reference value was determined by combining results from the three traceability routes. For all pairwise comparisons, the normalized error E n satisfied E n < 1, demonstrating metrological compatibility among the three results. The film thickness reference value obtained by the uncertainty-weighted method was (11.46 ± 0.14) nm (k = 2). This study provides a practical framework for consistency assessment, reference value determination, and cross-approach value transfer in nanoscale film thickness measurement. The stated expanded uncertainties correspond to the components included in the adopted measurement models.
Authors
- 董思禹 Dong Siyu
- Xinbin Cheng (ORCID: https://orcid.org/0000-0002-3855-483X)
- Wenzhe Zou
- Zhangning Xie (ORCID: https://orcid.org/0000-0002-5318-4363)
- Jingyuan Zhu (ORCID: https://orcid.org/0009-0003-7521-4118)
- Yuying Xie (ORCID: https://orcid.org/0009-0003-1396-1038)
- Dongbai Xue (ORCID: https://orcid.org/0009-0008-8384-6066)
- Tongbao Li
- Yuhang Fan (ORCID: https://orcid.org/0009-0004-0826-0795)
- Xiao Deng
Institutions
- Tongji University (CN)
- Shanghai Institute of Measurement and Testing Technology (CN)
Publication Details
- Journal
- Physica Scripta
- Published
- 2026-11-26
- DOI
- https://doi.org/10.1088/1402-4896/aec743
- Primary Topic
- Scientific Measurement and Uncertainty Evaluation
- Type
- article
- Field-Weighted Citation Impact
- 0.00