Borophene-Gold Nanohybrid Immunosensor for In Situ EV Lysis and Cancer Biomarker Detection by Electrochemical Impedance Spectroscopy

Extracellular vesicle (EV)-derived biomarkers provide valuable molecular information for early cancer detection and disease monitoring, yet their analysis typically requires labor-intensive EV isolation and chemical lysis, limiting access and increasing assay complexity. Here, we present a label-free, non-faradaic electrochemical impedance spectroscopy (nf-EIS) biosensor based on liquid-phase-exfoliated borophene (BP) integrated onto gold electrodes for direct detection of circulating and EV-derived biomarkers in serum. BP-Au interface provides an electrochemically active, high-capacitance sensing surface via interfacial charge transfer and orbital interactions, while electron-deficient boron sites enable direct coordination with glutaraldehyde and stable antibody immobilization without insulating linker layers. To improve biomarker accessibility, we investigated two reagent-free electric-field (EF) strategies: post-capture EV permeabilization and direct high-frequency (HF) EF treatment of serum. Direct HF EF treatment temporarily permeabilized EV membranes, quickly transporting biomarkers to the sensor, enhancing target capture and nf-EIS response. Compared to EV isolation, serum HF EF treatment reduced assay time to 45 min and improved biomarker recovery. The platform achieved limit of detection ranging from 0.02 to 0.57 pg/mL for five clinically relevant EV biomarkers (TSG101, GM2AP, MUC1, MUC5AC, and EGFR). Clinical evaluation of serum samples from healthy subjects (n = 20) and lung cancer patients (n = 20) showed improved sensing performance, increasing ROC-AUC values from 0.870−0.984 to 0.985−1.000 and sensitivity by up to 16.7% following HF EF-treatment. These findings demonstrate that integrating BP-enabled signal amplification with EF-assisted EV biomarker release provides a rapid, reagent-free, and isolation-free nf-EIS platform for sensitive, multiplexed liquid biopsy, with potential for early cancer detection and decentralized clinical diagnostics.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2026-11-27
DOI
https://doi.org/10.1021/acsami.6c17850
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Borophene-Gold Nanohybrid Immunosensor for In Situ EV Lysis and Cancer Biomarker Detection by Electrochemical Impedance Spectroscopy

Palash Kumar Basu, Nusrat Praween, Anoop Thattungal Manoharan
ACS Applied Materials & Interfaces
Electrochemical sensors and biosensors
article

Borophene-Gold Nanohybrid Immunosensor for In Situ EV Lysis and Cancer Biomarker Detection by Electrochemical Impedance Spectroscopy

Palash Kumar Basu, Nusrat Praween, Anoop Thattungal Manoharan
article en

Abstract

Extracellular vesicle (EV)-derived biomarkers provide valuable molecular information for early cancer detection and disease monitoring, yet their analysis typically requires labor-intensive EV isolation and chemical lysis, limiting access and increasing assay complexity. Here, we present a label-free, non-faradaic electrochemical impedance spectroscopy (nf-EIS) biosensor based on liquid-phase-exfoliated borophene (BP) integrated onto gold electrodes for direct detection of circulating and EV-derived biomarkers in serum. BP-Au interface provides an electrochemically active, high-capacitance sensing surface via interfacial charge transfer and orbital interactions, while electron-deficient boron sites enable direct coordination with glutaraldehyde and stable antibody immobilization without insulating linker layers. To improve biomarker accessibility, we investigated two reagent-free electric-field (EF) strategies: post-capture EV permeabilization and direct high-frequency (HF) EF treatment of serum. Direct HF EF treatment temporarily permeabilized EV membranes, quickly transporting biomarkers to the sensor, enhancing target capture and nf-EIS response. Compared to EV isolation, serum HF EF treatment reduced assay time to 45 min and improved biomarker recovery. The platform achieved limit of detection ranging from 0.02 to 0.57 pg/mL for five clinically relevant EV biomarkers (TSG101, GM2AP, MUC1, MUC5AC, and EGFR). Clinical evaluation of serum samples from healthy subjects (n = 20) and lung cancer patients (n = 20) showed improved sensing performance, increasing ROC-AUC values from 0.870−0.984 to 0.985−1.000 and sensitivity by up to 16.7% following HF EF-treatment. These findings demonstrate that integrating BP-enabled signal amplification with EF-assisted EV biomarker release provides a rapid, reagent-free, and isolation-free nf-EIS platform for sensitive, multiplexed liquid biopsy, with potential for early cancer detection and decentralized clinical diagnostics.

ACS Applied Materials & Interfaces
Regional Cancer Center, Thiruvananthapuram (IN), Indian Institute of Space Science and Technology (IN)
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.