Aortic arch reconstruction using a fan-shaped autologous pulmonary artery patch: a report of two cases

Autologous pulmonary artery tissue has recently been reported as a useful reconstructive material for aortic arch repair in infants with arch hypoplasia. We describe two infants with coarctation of the aorta associated with marked aortic arch hypoplasia who underwent aortic arch reconstruction using a fan-shaped autologous pulmonary artery patch. Two infants with coarctation of the aorta and a hypoplastic aortic arch underwent surgical repair. Case 1 was a 2-month-old girl weighing 4.7 kg with coarctation of the aorta, aortic arch hypoplasia, and a ventricular septal defect who presented with ductal shock. Case 2 was a 20-day-old boy weighing 2.9 kg with prenatally diagnosed coarctation of the aorta, arch hypoplasia, a ventricular septal defect, and a large patent ductus arteriosus. In both patients, the anterior wall of the main pulmonary artery was harvested and fashioned into a fan-shaped patch. The patch was tailored using preoperative computed tomography measurements, including the circumference of the descending aorta, to obtain a gradual transition in arch caliber. Ventricular septal defect closure was performed in Case 1, whereas pulmonary artery banding was performed in Case 2. The postoperative course was uneventful in both cases. Early postoperative computed tomography demonstrated satisfactory arch morphology without airway compression. Furthermore, at the latest follow-up, there was no clinically significant obstruction of the reconstructed arch based on upper- and lower-extremity blood pressure measurements and transthoracic echocardiography, although mild residual flow acceleration was observed in Case 2. Aortic arch reconstruction using a fan-shaped autologous pulmonary artery patch is technically feasible in selected infants with coarctation of the aorta associated with marked arch hypoplasia. This technique enables patient-specific geometric augmentation of the aortic arch with satisfactory early postoperative results. Long-term follow-up is required to evaluate durability and late outcomes.

Authors

Institutions

Publication Details

Journal
General Thoracic and Cardiovascular Surgery Cases
Published
2026-11-26
DOI
https://doi.org/10.1186/s44215-026-00288-9
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Aortic arch reconstruction using a fan-shaped autologous pulmonary artery patch: a report of two cases

Shinya Ugaki, Koji Nomura, Hisayuki Hongu, Shota Ogura et al.
General Thoracic and Cardiovascular Surgery Cases
Congenital Heart Disease Studies
article

Aortic arch reconstruction using a fan-shaped autologous pulmonary artery patch: a report of two cases

Shinya Ugaki, Koji Nomura, Hisayuki Hongu, Shota Ogura, Toshikazu Shimizu
article en

Abstract

Autologous pulmonary artery tissue has recently been reported as a useful reconstructive material for aortic arch repair in infants with arch hypoplasia. We describe two infants with coarctation of the aorta associated with marked aortic arch hypoplasia who underwent aortic arch reconstruction using a fan-shaped autologous pulmonary artery patch. Two infants with coarctation of the aorta and a hypoplastic aortic arch underwent surgical repair. Case 1 was a 2-month-old girl weighing 4.7 kg with coarctation of the aorta, aortic arch hypoplasia, and a ventricular septal defect who presented with ductal shock. Case 2 was a 20-day-old boy weighing 2.9 kg with prenatally diagnosed coarctation of the aorta, arch hypoplasia, a ventricular septal defect, and a large patent ductus arteriosus. In both patients, the anterior wall of the main pulmonary artery was harvested and fashioned into a fan-shaped patch. The patch was tailored using preoperative computed tomography measurements, including the circumference of the descending aorta, to obtain a gradual transition in arch caliber. Ventricular septal defect closure was performed in Case 1, whereas pulmonary artery banding was performed in Case 2. The postoperative course was uneventful in both cases. Early postoperative computed tomography demonstrated satisfactory arch morphology without airway compression. Furthermore, at the latest follow-up, there was no clinically significant obstruction of the reconstructed arch based on upper- and lower-extremity blood pressure measurements and transthoracic echocardiography, although mild residual flow acceleration was observed in Case 2. Aortic arch reconstruction using a fan-shaped autologous pulmonary artery patch is technically feasible in selected infants with coarctation of the aorta associated with marked arch hypoplasia. This technique enables patient-specific geometric augmentation of the aortic arch with satisfactory early postoperative results. Long-term follow-up is required to evaluate durability and late outcomes.

General Thoracic and Cardiovascular Surgery CasesVol. 5(1)
Kyoto Prefectural University of Medicine (JP), Saitama Children's Medical Center (JP)
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon