Test–Retest Reliability of Linear and Nonlinear Center of Pressure Measures During Single- and Dual-Task Standing in Women with Fibromyalgia

Women with Fibromyalgia (FM) show impaired postural control and a high risk of falls. The reliability of center of pressure (CoP) measures under sensory and attentional demands remains unknown in FM. Objective: To determine the test–retest reliability of linear and nonlinear CoP variables during quiet standing under Single- and Dual-Task (ST, DT) conditions, with Eyes Open (EO) and Closed (EC). Methods: Fifteen women with FM (age 50.3 ± 9.3 years; BMI 27.7 ± 7.2 kg/m2) completed two sessions one week apart on a dual force platform (EO ST, EC ST, EO DT, EC DT). Relative reliability was assessed with the Intraclass Correlation Coefficient ICC (3,1), and absolute reliability with the Standard Error of Measurement (SEM), Minimal Detectable Change (MDC), and Bland–Altman analysis. Results: Linear variables showed poor-to-good relative reliability (ICC = 0.14–0.87), generally higher under EC, but their SEM% (18–105%) and MDC% (50–290%) never met the predefined thresholds. Nonlinear variables showed poor-to-good relative reliability (ICC = −0.03 to 0.76): mediolateral SampEn was the most consistent (ICC = 0.54–0.76), whereas the LyE were unstable (ICC = −0.03 to 0.59). The anteroposterior DFA scaling exponent was the only variable meeting the absolute thresholds in all conditions, despite poor-to-moderate ICC values. DT did not consistently reduce reliability. Conclusions: Linear CoP measures showed higher relative reliability than nonlinear metrics but large absolute errors, and relative and absolute reliability did not coincide. Nonlinear metrics should be considered exploratory, and individual changes smaller than the MDC should not be interpreted as real change.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-11-26
DOI
https://doi.org/10.3390/s26237467
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Test–Retest Reliability of Linear and Nonlinear Center of Pressure Measures During Single- and Dual-Task Standing in Women with Fibromyalgia

Santos Villafaina, Juan Luis Leon‐Llamas, Mari Carmen Gómez-Álvaro, Narcís Gusi et al.
Sensors
Balance, Gait, and Falls Prevention
article

Test–Retest Reliability of Linear and Nonlinear Center of Pressure Measures During Single- and Dual-Task Standing in Women with Fibromyalgia

Santos Villafaina, Juan Luis Leon‐Llamas, Mari Carmen Gómez-Álvaro, Narcís Gusi, María Melo-Alonso, Francisco Javier Domínguez‐Muñoz
article en

Abstract

Women with Fibromyalgia (FM) show impaired postural control and a high risk of falls. The reliability of center of pressure (CoP) measures under sensory and attentional demands remains unknown in FM. Objective: To determine the test–retest reliability of linear and nonlinear CoP variables during quiet standing under Single- and Dual-Task (ST, DT) conditions, with Eyes Open (EO) and Closed (EC). Methods: Fifteen women with FM (age 50.3 ± 9.3 years; BMI 27.7 ± 7.2 kg/m2) completed two sessions one week apart on a dual force platform (EO ST, EC ST, EO DT, EC DT). Relative reliability was assessed with the Intraclass Correlation Coefficient ICC (3,1), and absolute reliability with the Standard Error of Measurement (SEM), Minimal Detectable Change (MDC), and Bland–Altman analysis. Results: Linear variables showed poor-to-good relative reliability (ICC = 0.14–0.87), generally higher under EC, but their SEM% (18–105%) and MDC% (50–290%) never met the predefined thresholds. Nonlinear variables showed poor-to-good relative reliability (ICC = −0.03 to 0.76): mediolateral SampEn was the most consistent (ICC = 0.54–0.76), whereas the LyE were unstable (ICC = −0.03 to 0.59). The anteroposterior DFA scaling exponent was the only variable meeting the absolute thresholds in all conditions, despite poor-to-moderate ICC values. DT did not consistently reduce reliability. Conclusions: Linear CoP measures showed higher relative reliability than nonlinear metrics but large absolute errors, and relative and absolute reliability did not coincide. Nonlinear metrics should be considered exploratory, and individual changes smaller than the MDC should not be interpreted as real change.

SensorsVol. 26(23)
Universidade do Porto (PT), Centro de Investigación Biomédica en Red de Fragilidad y Envejecimiento Saludable (ES), Centro de Investigação em Actividade Física Saúde e Lazer (PT), Universidad de Extremadura (ES)
Balance, Gait, and Falls Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon