Association of Positive Airway Pressure With Non-Smoke Spontaneous Individual Contrast During Simulated Valsalva Loading

Background Microbubble testing during the Valsalva manoeuvre (VM) is essential for diagnosing patent foramen ovale (PFO), but non-smoke spontaneous individual contrast (NSSIC) may mimic right-to-left shunt (RLS). We investigated the association between graded positive airway pressure during simulated Valsalva loading and NSSIC. Methods This single-centre retrospective observational study included 35 consecutive patients undergoing transcatheter PFO closure between December 2024 and November 2025. Under general anaesthesia, positive airway pressures of 10, 20, and 30 cmH2O were applied for 10 seconds and abruptly released without contrast injection. Repeated measurements were analysed using mixed-effects logistic regression for left atrial (LA) NSSIC and generalized estimating equations for right atrial (RA) NSSIC. Results RA NSSIC occurred in 26/33 (78.8%), 34/35 (97.1%), and 34/35 (97.1%) at 10, 20, and 30 cmH2O. Compared with 10 cmH2O, the odds were higher at both 20 and 30 cmH2O (OR 8.985, 95% CI 1.332–60.62; p = 0.024 for both), with identical RA NSSIC status at 20 and 30 cmH2O. LA NSSIC increased from 3/33 (9.1%) to 11/35 (31.4%) and 23/35 (65.7%); each 10-cmH2O increase was associated with higher odds of LA NSSIC (OR 5.815, 95% CI 2.793–12.11; p < 0.001). Conclusions NSSIC occurrence increased with higher positive airway pressure during simulated Valsalva loading. Recognition of this phenomenon is important to avoid false-positive interpretation of RLS during microbubble testing for PFO.

Authors

Institutions

Publication Details

Journal
European Heart Journal - Imaging Methods and Practice
Published
2026-11-26
DOI
https://doi.org/10.1093/ehjimp/qyag202
Primary Topic
Cardiovascular and Diving-Related Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Association of Positive Airway Pressure With Non-Smoke Spontaneous Individual Contrast During Simulated Valsalva Loading

Eiji Toyosaki, Toshiro Shinke, Yasuhide Mochizuki, Hiroto Fukuoka et al.
European Heart Journal - Imaging Methods and Practice
Cardiovascular and Diving-Related Complications
article

Association of Positive Airway Pressure With Non-Smoke Spontaneous Individual Contrast During Simulated Valsalva Loading

Eiji Toyosaki, Toshiro Shinke, Yasuhide Mochizuki, Hiroto Fukuoka, Rumi Hachiya, Sakiko Gohbara, Saaya Ichikawa-Ogura, Ryota Kosaki, Ayaka Oda, Ken Oshima, Yumi Yamamoto, Mamiko Yamada
article en

Abstract

Background Microbubble testing during the Valsalva manoeuvre (VM) is essential for diagnosing patent foramen ovale (PFO), but non-smoke spontaneous individual contrast (NSSIC) may mimic right-to-left shunt (RLS). We investigated the association between graded positive airway pressure during simulated Valsalva loading and NSSIC. Methods This single-centre retrospective observational study included 35 consecutive patients undergoing transcatheter PFO closure between December 2024 and November 2025. Under general anaesthesia, positive airway pressures of 10, 20, and 30 cmH2O were applied for 10 seconds and abruptly released without contrast injection. Repeated measurements were analysed using mixed-effects logistic regression for left atrial (LA) NSSIC and generalized estimating equations for right atrial (RA) NSSIC. Results RA NSSIC occurred in 26/33 (78.8%), 34/35 (97.1%), and 34/35 (97.1%) at 10, 20, and 30 cmH2O. Compared with 10 cmH2O, the odds were higher at both 20 and 30 cmH2O (OR 8.985, 95% CI 1.332–60.62; p = 0.024 for both), with identical RA NSSIC status at 20 and 30 cmH2O. LA NSSIC increased from 3/33 (9.1%) to 11/35 (31.4%) and 23/35 (65.7%); each 10-cmH2O increase was associated with higher odds of LA NSSIC (OR 5.815, 95% CI 2.793–12.11; p < 0.001). Conclusions NSSIC occurrence increased with higher positive airway pressure during simulated Valsalva loading. Recognition of this phenomenon is important to avoid false-positive interpretation of RLS during microbubble testing for PFO.

European Heart Journal - Imaging Methods and Practice
SHOWA Medical University (JP)
Cardiovascular and Diving-Related Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon