Two estimation methods agree on fit but disagree up to tenfold on the binding constant: practical non-identifiability and its prediction consequences in a simulated denosumab-like quasi-steady-state target-mediated drug disposition model

The quasi-steady-state (QSS) approximation to target-mediated drug disposition (TMDD) summarises drug–target binding in one constant, K ss. Structural identifiability of this class is established; whether a sparse design estimates that constant precisely, and what imprecision costs, are separate questions. We simulated 24 replicate datasets from a simplified denosumab-like two-compartment QSS-TMDD model (60 mg subcutaneously at 0, 6 and 12 months; 30 subjects; 24 samples each) and fitted each by two estimators: stochastic approximation expectation–maximisation (SAEM) under multistart initialisation, and first-order conditional estimation with interaction (FOCEi). Under one common objective evaluated at fixed parameters the two estimators differ by at most 7.6 units on every replicate, with no fit identifiable as an optimisation failure, while their K ss estimates differ by up to tenfold. K ss fails the prespecified precision criterion under both — 58.9% and 42.0% relative standard deviation against 23.8% and 22.3% for the next-worst parameter — so the ranking is estimator-independent. The single-fit standard error reports 15.9% and 9.6%, understating the spread 3.7- and 4.4-fold, and is uninformative in two fits (relative standard error 1832% and 173%). Replacing only K ss in the true vector moves predicted drug concentration by 1.4–1.5% and predicted free target by 24.8–28.0%, an approximately 18-fold asymmetry under all three estimate sets. This points to measuring the target rather than sampling the drug more densely, and agreement of two estimators on the objective with disagreement on a parameter is a direct test of practical non-identifiability.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-26
DOI
https://doi.org/10.21203/rs.3.rs-11744808/v1
Primary Topic
Statistical Methods in Clinical Trials
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Two estimation methods agree on fit but disagree up to tenfold on the binding constant: practical non-identifiability and its prediction consequences in a simulated denosumab-like quasi-steady-state target-mediated drug disposition model

Jyotheeshwar Akshay Ravikumar, B. Anbarasan
Research Square
Statistical Methods in Clinical Trials
preprint

Two estimation methods agree on fit but disagree up to tenfold on the binding constant: practical non-identifiability and its prediction consequences in a simulated denosumab-like quasi-steady-state target-mediated drug disposition model

Jyotheeshwar Akshay Ravikumar, B. Anbarasan
preprint en

Abstract

The quasi-steady-state (QSS) approximation to target-mediated drug disposition (TMDD) summarises drug–target binding in one constant, K ss. Structural identifiability of this class is established; whether a sparse design estimates that constant precisely, and what imprecision costs, are separate questions. We simulated 24 replicate datasets from a simplified denosumab-like two-compartment QSS-TMDD model (60 mg subcutaneously at 0, 6 and 12 months; 30 subjects; 24 samples each) and fitted each by two estimators: stochastic approximation expectation–maximisation (SAEM) under multistart initialisation, and first-order conditional estimation with interaction (FOCEi). Under one common objective evaluated at fixed parameters the two estimators differ by at most 7.6 units on every replicate, with no fit identifiable as an optimisation failure, while their K ss estimates differ by up to tenfold. K ss fails the prespecified precision criterion under both — 58.9% and 42.0% relative standard deviation against 23.8% and 22.3% for the next-worst parameter — so the ranking is estimator-independent. The single-fit standard error reports 15.9% and 9.6%, understating the spread 3.7- and 4.4-fold, and is uninformative in two fits (relative standard error 1832% and 173%). Replacing only K ss in the true vector moves predicted drug concentration by 1.4–1.5% and predicted free target by 24.8–28.0%, an approximately 18-fold asymmetry under all three estimate sets. This points to measuring the target rather than sampling the drug more densely, and agreement of two estimators on the objective with disagreement on a parameter is a direct test of practical non-identifiability.

Research Square
Sri Ramachandra Institute of Higher Education and Research (IN)
Statistical Methods in Clinical Trials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Two estimation methods agree on fit but disagree up to tenfold on the binding constant: practical non-identifiability and its prediction consequences in a simulated denosumab-like quasi-steady-state target-mediated drug disposition model — Jyotheeshwar Akshay Ravikumar, B. Anbarasan · Research Square (2026) | TGRS Research Map | TGRS