The significate of central venous pressure in pediatric intensive care

The aim of the research. To identify and evaluate factors influencing central venous pressure values in pediatric intensive care. To determine the informative value of central venous pressure (CVP) indicators and the feasibility of their use in routine pediatric intensive care. Materials and methods. The study included 452 children aged 4 weeks to 18 years, weighing 2,2 kg to 105 kg, treated in the intensive care unit for hemodynamic and volume depletion in emergency and critical conditions. All patients had a central venous catheter (CVC). CVP was measured discretely using the Waldman technique through a single- or multi-lumen CVC inserted into one of the main veins of the superior vena cava. The first measurement was taken immediately after CVC insertion, with the value recorded according to the standard (hospital-accepted) central venous catheterization protocol. Subsequent measurements were performed as needed to obtain information on CVP levels. Ultrasound, ECG, and X-ray monitoring were used to verify the position of the intravascular «tip» of the CVC. The assessment of CVP parameters was carried out in combination with the obtained anamnestic, clinical, laboratory data, available polyparametric monitoring of the pulmonary function and the possibilities of additional studies (ultrasound, echocardiography) of the volume status and central hemodynamic parameters. Results. Multiple factors influencing the level and unreliability of CVP measurements have been identified. These include: incorrect CVC positioning, catheter-associated thrombosis, and inadvertent administration of adrenergic boluses during CVP measurement. Conclusion. The use of CVP monitoring is appropriate in assessing the volume status and the nature of hemodynamic disturbances in children in emergency and critical conditions only taking into account the factors influencing its level and the relationship with other clinical, laboratory and monitoring indicators.

Authors

Institutions

Publication Details

Journal
Zabajkalʹskij medicinskij vestnik
Published
2026-11-26
DOI
https://doi.org/10.52485/19986173_2026_3_20
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The significate of central venous pressure in pediatric intensive care

Д. А. Смирнов, Валентин Вячеславович Сытьков, Владимир Геннадьевич Багаев, М. В. Быков et al.
Zabajkalʹskij medicinskij vestnik
Hemodynamic Monitoring and Therapy
article

The significate of central venous pressure in pediatric intensive care

Д. А. Смирнов, Валентин Вячеславович Сытьков, Владимир Геннадьевич Багаев, М. В. Быков, Vladimir V. Lazarev, Boris I. Golubev, A.D. Mayorov, Mariya S. Tsesareva, Nikolay S. Frolov, Vyacheslav S. Nafikov, Tatiana A. Pchelicnceva, A. A. Konovalova, A. S. Privalov, A. V. Sapron
article en

Abstract

The aim of the research. To identify and evaluate factors influencing central venous pressure values in pediatric intensive care. To determine the informative value of central venous pressure (CVP) indicators and the feasibility of their use in routine pediatric intensive care. Materials and methods. The study included 452 children aged 4 weeks to 18 years, weighing 2,2 kg to 105 kg, treated in the intensive care unit for hemodynamic and volume depletion in emergency and critical conditions. All patients had a central venous catheter (CVC). CVP was measured discretely using the Waldman technique through a single- or multi-lumen CVC inserted into one of the main veins of the superior vena cava. The first measurement was taken immediately after CVC insertion, with the value recorded according to the standard (hospital-accepted) central venous catheterization protocol. Subsequent measurements were performed as needed to obtain information on CVP levels. Ultrasound, ECG, and X-ray monitoring were used to verify the position of the intravascular «tip» of the CVC. The assessment of CVP parameters was carried out in combination with the obtained anamnestic, clinical, laboratory data, available polyparametric monitoring of the pulmonary function and the possibilities of additional studies (ultrasound, echocardiography) of the volume status and central hemodynamic parameters. Results. Multiple factors influencing the level and unreliability of CVP measurements have been identified. These include: incorrect CVC positioning, catheter-associated thrombosis, and inadvertent administration of adrenergic boluses during CVP measurement. Conclusion. The use of CVP monitoring is appropriate in assessing the volume status and the nature of hemodynamic disturbances in children in emergency and critical conditions only taking into account the factors influencing its level and the relationship with other clinical, laboratory and monitoring indicators.

Zabajkalʹskij medicinskij vestnik(3)
Pirogov Russian National Research Medical University (RU), Children's Scientific and Clinical Center for Infectious Diseases of the Federal Medical and Biological Agency (RU), St. Vladimir Children's Moscow Clinical Hospital (RU), Ministry of Health of the Russian Federation (RU), Chita State Academy of Medicine (RU)
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon