Delayed Reduction in Heating-Water Use After an Apartment Retrofit and a Change of Household: A Billing-Data Case Study over Two Heating Seasons
Retrofit outcomes are often judged from one post-retrofit year, although occupants and heating operation may also change. This study analysed 55 months of bills for a 169 m2 apartment unit in Goyang, South Korea, which received internal vacuum-insulation panels, new windows, and new finishes in late 2024 before a different household moved in. Its flow meter recorded only the volume of district heating (DH) water for space heating. Change-point, segmented-regression, and interrupted time-series models were applied. The previous household’s use had already fallen by about one third without physical change. In the first post-retrofit winter, the weather-normalized DH water volume was 0.5% below the prediction (68% interval ±30 percentage points). In the second post-retrofit heating season (2025–2026), it was 71.0% below a baseline representing the previous household’s use in 2022–2023 (68% interval ±23 percentage points) and 49–56% below that household’s latest pre-retrofit state (25% if its earlier decline is extrapolated linearly); because the household changed and the supply–return temperature difference was not recorded, this is a combined change in heating-related water use, not a retrofit energy saving. Electricity use rose by about 7%, within its 90% interval. Here, the first winter alone would not have revealed the change.
Authors
- Byonghu Sohn
- Jihoon Jang (ORCID: https://orcid.org/0000-0002-1711-1255)
- Jae-Sik Kang
Institutions
- Korea Institute of Civil Engineering and Building Technology (KR)
Publication Details
- Journal
- Buildings
- Published
- 2026-11-26
- DOI
- https://doi.org/10.3390/buildings16234742
- Primary Topic
- Building Energy and Comfort Optimization
- Type
- article
- Field-Weighted Citation Impact
- 0.00