Platform differences: Retropulsion, fragmentation, and dust in pulsed thulium: YAG lithotripsy

OBJECTIVE: Our objective was to compare bubble appearance, retropulsion kinetics, and lithotripsy efficiency between two pulsed Thulium:yttrium-aluminium-garnet laser platforms with distinct engineering characteristics, including pumping configuration and peak-power capability. MATERIALS AND METHODS: We compared the RevoLix HTL (LISA Laser Products GmbH) and the Thulio (Dornier MedTech GmbH) across six settings (0.2-1.0 J, 10-50 Hz, short/long pulse). Standardized 5 × 5 × 5 mm artificial stones on a V-shaped rail and calcium oxalate dihydrate dust from one clinical case were evaluated. Imaging was used to qualitatively assess bubbles, and Kinovea and a custom Python pipeline quantified the retropulsion and dust particle area. An equal-weight composite score summarized stone weight loss and retropulsion. RESULTS: Qualitative imaging demonstrated that the RevoLix HTL produced well-defined bubble outlines, whereas the Thulio generated less defined outlines. The Thulio showed pulsatile retropulsion, whereas the RevoLix HTL exhibited smoother displacement and lower mean retropulsion at all six settings (e.g., 1.0 J/10 Hz long pulse: mean ± standard deviation [SD] 3.1 ± 0.6 vs. 15.3 ± 2.1 mm; mean difference -12.1 mm [95% confidence interval -15.3 to -8.9]). In fixed-stone tests, the Thulio achieved greater stone weight loss at 0.4 J/25 Hz long pulse (mean ± SD 17.5 ± 5.0 vs. 35.0 ± 5.8 mg; mean difference -17.5 mg [95% confidence interval -26.9 to -8.1]). At equal weighting, RevoLix HTL had a higher composite score at five of six settings, although the ranking was weighting dependent. Exploratory particle analysis showed smaller particle areas with RevoLix HTL at all three settings. CONCLUSION: Despite sharing the same pulsed Thulium:yttrium-aluminium-garnet laser medium, the two platforms exhibited distinct laser-stone interaction profiles. Further clinical evaluation is warranted to determine the relevance of these differences.

Authors

Institutions

Publication Details

Journal
British Journal of Urology
Published
2026-11-26
DOI
https://doi.org/10.1111/bju.70565
Primary Topic
Kidney Stones and Urolithiasis Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Platform differences: Retropulsion, fragmentation, and dust in pulsed thulium: YAG lithotripsy

Takashi Yoshida, Takahiro Nakamoto, Kazuyoshi Nakao, Gen Kawa et al.
British Journal of Urology
Kidney Stones and Urolithiasis Treatments
article

Platform differences: Retropulsion, fragmentation, and dust in pulsed thulium: YAG lithotripsy

Takashi Yoshida, Takahiro Nakamoto, Kazuyoshi Nakao, Gen Kawa, Yusuke Motoki, Yusuke Shirasu
article en

Abstract

OBJECTIVE: Our objective was to compare bubble appearance, retropulsion kinetics, and lithotripsy efficiency between two pulsed Thulium:yttrium-aluminium-garnet laser platforms with distinct engineering characteristics, including pumping configuration and peak-power capability. MATERIALS AND METHODS: We compared the RevoLix HTL (LISA Laser Products GmbH) and the Thulio (Dornier MedTech GmbH) across six settings (0.2-1.0 J, 10-50 Hz, short/long pulse). Standardized 5 × 5 × 5 mm artificial stones on a V-shaped rail and calcium oxalate dihydrate dust from one clinical case were evaluated. Imaging was used to qualitatively assess bubbles, and Kinovea and a custom Python pipeline quantified the retropulsion and dust particle area. An equal-weight composite score summarized stone weight loss and retropulsion. RESULTS: Qualitative imaging demonstrated that the RevoLix HTL produced well-defined bubble outlines, whereas the Thulio generated less defined outlines. The Thulio showed pulsatile retropulsion, whereas the RevoLix HTL exhibited smoother displacement and lower mean retropulsion at all six settings (e.g., 1.0 J/10 Hz long pulse: mean ± standard deviation [SD] 3.1 ± 0.6 vs. 15.3 ± 2.1 mm; mean difference -12.1 mm [95% confidence interval -15.3 to -8.9]). In fixed-stone tests, the Thulio achieved greater stone weight loss at 0.4 J/25 Hz long pulse (mean ± SD 17.5 ± 5.0 vs. 35.0 ± 5.8 mg; mean difference -17.5 mg [95% confidence interval -26.9 to -8.1]). At equal weighting, RevoLix HTL had a higher composite score at five of six settings, although the ranking was weighting dependent. Exploratory particle analysis showed smaller particle areas with RevoLix HTL at all three settings. CONCLUSION: Despite sharing the same pulsed Thulium:yttrium-aluminium-garnet laser medium, the two platforms exhibited distinct laser-stone interaction profiles. Further clinical evaluation is warranted to determine the relevance of these differences.

British Journal of Urology
Kansai Medical University (JP), Saiseikai Ibaraki Hospital (JP)
Kidney Stones and Urolithiasis Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon