Detection of Ketone Bodies by Cost-Effective Polymers-Coated Patch from Surrogate Matrix of Urine

Rapid detection of ketone bodies is important for the timely assessment of diabetic ketoacidosis, a life-threatening metabolic complication in diabetes. This study designed a glass fiber-based microextraction patch coated with divinylbenzene/polydimethylsiloxane to extract acetone, β-hydroxybutyrate (BHB), and ethyl acetoacetate (EAA) ketone bodies from phosphate-buffered saline (PBS), a surrogate urine matrix. Acetone and BHB were selected as physiological ketone-related targets, whereas EAA was chosen as a model compound of acetoacetate because the original analyte (acetoacetate) is chemically unstable. Characterization by FE-SEM, EDAX, FTIR, and thermogravimetric analysis confirmed the uniform morphology, successful coating deposition, and good thermal stability of the fabricated patches. The extraction method was optimized by evaluating the desorption solvent, pH, extraction and desorption times, temperature, and stirring rate. Following direct-immersion extraction, the analytes were desorbed with methanol and quantified by gas chromatography-tandem mass spectrometry. The concentration-dependent calibration curves over a range of 100–900 ng/mL exhibited good linearity (r2 = 0.96–0.99). The fabricated patches provided a simple and cost-effective sampling platform for laboratory-scale applications. This study enabled the evaluation of multiple ketone bodies with different physicochemical properties on a single platform. The environmental sustainability of the method was evaluated using the Analytical Greenness Metric (AGREE, 0.78), the Blue Applicability grade Index (BAGI, 70), and the Carbon Footprint Reduction Index (CaFRI, 88), demonstrating good analytical performance with a reduced environmental footprint. These findings show the potential of the developed glass fiber-based patches as a cost-effective, environmentally sustainable sampling platform for ketone body analysis and provide a foundation for future evaluation in clinically relevant biological matrices. However, future validation in real biological matrices is required before considering this technique for clinical use.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2026-11-26
DOI
https://doi.org/10.1021/acsomega.6c10239
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Detection of Ketone Bodies by Cost-Effective Polymers-Coated Patch from Surrogate Matrix of Urine

Koushik Handattu, Chiranjit Ghosh, Sumati Vithalrao Kulkarni
ACS Omega
Analytical chemistry methods development
article

Detection of Ketone Bodies by Cost-Effective Polymers-Coated Patch from Surrogate Matrix of Urine

Koushik Handattu, Chiranjit Ghosh, Sumati Vithalrao Kulkarni
article en

Abstract

Rapid detection of ketone bodies is important for the timely assessment of diabetic ketoacidosis, a life-threatening metabolic complication in diabetes. This study designed a glass fiber-based microextraction patch coated with divinylbenzene/polydimethylsiloxane to extract acetone, β-hydroxybutyrate (BHB), and ethyl acetoacetate (EAA) ketone bodies from phosphate-buffered saline (PBS), a surrogate urine matrix. Acetone and BHB were selected as physiological ketone-related targets, whereas EAA was chosen as a model compound of acetoacetate because the original analyte (acetoacetate) is chemically unstable. Characterization by FE-SEM, EDAX, FTIR, and thermogravimetric analysis confirmed the uniform morphology, successful coating deposition, and good thermal stability of the fabricated patches. The extraction method was optimized by evaluating the desorption solvent, pH, extraction and desorption times, temperature, and stirring rate. Following direct-immersion extraction, the analytes were desorbed with methanol and quantified by gas chromatography-tandem mass spectrometry. The concentration-dependent calibration curves over a range of 100–900 ng/mL exhibited good linearity (r2 = 0.96–0.99). The fabricated patches provided a simple and cost-effective sampling platform for laboratory-scale applications. This study enabled the evaluation of multiple ketone bodies with different physicochemical properties on a single platform. The environmental sustainability of the method was evaluated using the Analytical Greenness Metric (AGREE, 0.78), the Blue Applicability grade Index (BAGI, 70), and the Carbon Footprint Reduction Index (CaFRI, 88), demonstrating good analytical performance with a reduced environmental footprint. These findings show the potential of the developed glass fiber-based patches as a cost-effective, environmentally sustainable sampling platform for ketone body analysis and provide a foundation for future evaluation in clinically relevant biological matrices. However, future validation in real biological matrices is required before considering this technique for clinical use.

ACS Omega
Manipal Academy of Higher Education (IN), Kasturba Medical College, Manipal (IN)
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon