An Explainable Depthwise Separable-Fire Convolutional Model for Resource-Constrained Diagnosis of Cardiac Rhythm
Cardiac rhythm monitoring requires high accuracy, speed, and energy efficiency to enable continuous use in wearable and bedside monitoring devices. In this study, we perform fine-grained classification of 16 MIT-BIH beat annotation categories. We propose LEDSNet, a lightweight one-dimensional convolutional network that achieves 98.58% accuracy and 98.57% F1-score, with no classes left undetected, on the MITBIH Arrhythmia dataset under a segment-wise evaluation protocol. Patient-wise splitting was not feasible for the full 16-class setting because several rare beat types occur in only a single patient/record. Therefore, to additionally assess patient-independent generalization, we performed a complementary patient-wise evaluation using a 5-class AAMI mapping, where LEDSNet achieved 92.90% accuracy, 92.75% precision, 92.90% recall, and 92.40% F1-score. To address the heavy class imbalance in the arrhythmia dataset, we used a class-conditional Wasserstein GAN with a gradient penalty for data augmentation, which outperformed SMOTE. A systematic five-stage ablation study validated the optimal architecture and hyperparameters. A 10-fold stratified training-validation stability analysis, in which models from different training-validation folds were evaluated on the same fixed hold-out test set, demonstrated stable performance under the same segment-wise protocol with a mean accuracy of 98.51% ± 0.07%. The model requires only 0.11 MB of memory and $$1.4\times 10^5$$ FLOPs, reducing training energy consumption and estimated $$\text {CO}_{2eq}$$ emissions by at least 37.78% compared with previous lightweight models. For deployment evidence, inference on a Raspberry Pi 4 Model B classified 31,713 pre-segmented beats in just 3.58 s (about 8,855 segments/s). Besides, LIME-based analysis suggests the model focuses on clinically meaningful waveform regions. Overall, the results indicate that efficient multi-class beat-type classification is feasible on resource-constrained devices.
Authors
- Abdullah Al-Mamun Bulbul (ORCID: https://orcid.org/0000-0002-5652-2065)
- Mohammad Ali Moni (ORCID: https://orcid.org/0000-0003-0756-1006)
- Md. Abdul Awal (ORCID: https://orcid.org/0000-0003-3028-4932)
- Saad Aloteibi (ORCID: https://orcid.org/0000-0002-0510-4381)
- Moid Sandhu
Institutions
- Khulna University (BD)
- Commonwealth Scientific and Industrial Research Organisation (AU)
- Charles Sturt University (AU)
- Queensland University of Technology (AU)
- The University of Queensland (AU)
- University of Southern Queensland (AU)
- King Saud University (SA)
- Australian e-Health Research Centre (AU)
Publication Details
- Journal
- International Journal of Computational Intelligence Systems
- Published
- 2026-11-26
- DOI
- https://doi.org/10.1007/s44196-026-01696-z
- Primary Topic
- ECG Monitoring and Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00