Lightweight clinical decision support for premature ventricular contraction detection using unscented Kalman filter

Objectives: This study proposes a lightweight and interpretable pre-classification framework for automated detection of Premature Ventricular Contractions (PVC) in ambulatory Electrocardiogram (ECG) monitoring. Methods: The approach leverages an Unscented Kalman Filter (UKF) combined with a cylindrical dynamic model, called Cylindrical UKF (CUKF) for ECG. Deviations from normal sinus rhythm are quantified via the innovation residual, measured using the Normalized Mean Square Error (NMSE), serving as a digital biomarker. The model was evaluated using the MIT-BIH Arrhythmia Database, with adaptive thresholds determined through 10-fold cross-validation. Results: The proposed method achieved a Macro F1-score of 0.8924 ± 0.0160, with average sensitivity of 85.83% ± 3.44% and specificity above 92%. Conclusion: This framework offers an efficient alternative to data-intensive approaches, requiring low computational resources and linear time complexity. Its design makes it suitable for real-time deployment in wearable devices and as a pre-screening module within digital health systems, supporting clinical decision-making in large-scale ECG monitoring.

Authors

Institutions

Publication Details

Journal
Journal of Health Informatics
Published
2026-11-26
DOI
https://doi.org/10.59681/2175-4411.v18.iespecial.2026.1811
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Lightweight clinical decision support for premature ventricular contraction detection using unscented Kalman filter

Renata Coelho Borges, Victor Baptista Frencl, Lucas Kenzo Araki
Journal of Health Informatics
ECG Monitoring and Analysis
article

Lightweight clinical decision support for premature ventricular contraction detection using unscented Kalman filter

Renata Coelho Borges, Victor Baptista Frencl, Lucas Kenzo Araki
article en

Abstract

Objectives: This study proposes a lightweight and interpretable pre-classification framework for automated detection of Premature Ventricular Contractions (PVC) in ambulatory Electrocardiogram (ECG) monitoring. Methods: The approach leverages an Unscented Kalman Filter (UKF) combined with a cylindrical dynamic model, called Cylindrical UKF (CUKF) for ECG. Deviations from normal sinus rhythm are quantified via the innovation residual, measured using the Normalized Mean Square Error (NMSE), serving as a digital biomarker. The model was evaluated using the MIT-BIH Arrhythmia Database, with adaptive thresholds determined through 10-fold cross-validation. Results: The proposed method achieved a Macro F1-score of 0.8924 ± 0.0160, with average sensitivity of 85.83% ± 3.44% and specificity above 92%. Conclusion: This framework offers an efficient alternative to data-intensive approaches, requiring low computational resources and linear time complexity. Its design makes it suitable for real-time deployment in wearable devices and as a pre-screening module within digital health systems, supporting clinical decision-making in large-scale ECG monitoring.

Journal of Health InformaticsVol. 18(Especial)
Universidade Tecnológica Federal do Paraná (BR)
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon