Seismic Refraction Assessment of Near-surface Engineering Properties for Foundation Designing at Akwa Ibom State University and Environs, Southeast Nigeria
Rapid infrastructural and industrial expansion across Akwa Ibom State University and its surrounding communities in southeastern Nigeria demands rigorous near-surface characterization to guide safe foundation design within the physically challenging Niger Delta terrain. Expanding significantly beyond the spatial footprint of earlier localized shallow investigations, this study integrates seismic refraction profiling with empirically derived geotechnical parameters to evaluate subsurface load-bearing competency across elevations ranging from 9.0 to 19.0 m above sea level. Forward and reverse seismic refraction surveys were conducted using explosive sources and a 24-channel OYO McSEIS seismograph to measure compressional wave velocities (Vp), while shear wave velocities (Vs) were modeled through a regionally calibrated empirical Vp–Vs relationship. These velocity datasets were used to compute critical elastic and engineering indices, including porosity, void ratio, bulk density, Poisson’s ratio, Young’s, bulk, and shear moduli, Lamé’s first parameter, material index, and seismic proxies for ultimate and allowable bearing capacities. Subsurface modeling delineates a predominantly two-layer, near-horizontal velocity structure. The upper weathering horizon comprises loose, unconsolidated lateritic soil (5.00–9.19 m thick) characterized by low Vp (377.05–805.50 m/s), Vs (170.82–366.39 m/s), an average density of ~ 1,634.3 kg/m³, and low allowable bearing capacity proxies (0.000020–0.000090 GPa), rendering it poorly suited for heavy structural loads without ground improvement. In contrast, the underlying consolidated stratum extends beyond the maximum investigation depth with markedly higher Vp (1,643.10–2,000.00 m/s), an average density of ~ 1,637.0 kg/m³, allowable bearing capacity proxies of 0.000300–0.000369 GPa, and ultimate bearing capacity proxies of 0.00120–0.00149 GPa, establishing it as the primary competent founding horizon. Spatial evaluation also reveals a notable geotechnical anomaly around Ikot Aba in the western sector, where elevated ultimate bearing capacities coincide across both the upper and lower strata. By synthesizing these multi-parameter results into a novel engineering competency zonation map, this work provides civil engineers and urban planners with an actionable spatial framework for optimizing foundation depths and mitigating structural risk across the developing university corridor.
Authors
- Nyakno Jimmy George (ORCID: https://orcid.org/0000-0003-2793-4244)
- Nsikak Edet Bassey
Institutions
- Akwa Ibom State University (NG)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-26
- DOI
- https://doi.org/10.21203/rs.3.rs-11742261/v1
- Primary Topic
- Geotechnical and construction materials studies
- Type
- preprint