Fourier-Transform Photothermal Spectroscopy with Transient-Lens Detection

We demonstrate Fourier-transform photothermal spectroscopy using broadband supercontinuum excitation and transient-lens detection. The output of a Ti:sapphire oscillator is broadened in a photonic crystal fiber to generate the supercontinuum pump, which is converted into a phase-stable pulse pair with a controllable femtosecond delay using a birefringent interferometer. The absorption-induced heating from the pump generates a transient thermal lens in the sample, which is detected as a function of delay by an off-resonant 800 nm photothermal probe beam. Fourier transform of the interferometric photothermal response yields a frequency-domain signal corresponding to the sample absorptance spectrum weighted by the pump spectrum. After division by the measured pump spectrum, the reconstructed photothermal spectrum is compared with a direct frequency-domain linear absorption measurement to evaluate the accuracy of the reconstruction. This method combines Fourier-transform broadband excitation with thermal-lens readout, allowing broadband linear absorption spectra to be obtained from pump-induced refractive-index changes rather than from transmitted excitation intensity. We demonstrate the method on phloxine B.

Authors

Publication Details

Journal
arXiv
Published
2026-11-25
DOI
https://doi.org/10.48550/arxiv.2611.34361
Primary Topic
Spectroscopy and Laser Applications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Fourier-Transform Photothermal Spectroscopy with Transient-Lens Detection

Jennifer P. Ogilvie, Asha S. Thomas, Muyi Zhang, Toluwatomi Haastrup et al.
arXiv
Spectroscopy and Laser Applications
preprint

Fourier-Transform Photothermal Spectroscopy with Transient-Lens Detection

Jennifer P. Ogilvie, Asha S. Thomas, Muyi Zhang, Toluwatomi Haastrup, Luzhou Yu
preprint en

Abstract

We demonstrate Fourier-transform photothermal spectroscopy using broadband supercontinuum excitation and transient-lens detection. The output of a Ti:sapphire oscillator is broadened in a photonic crystal fiber to generate the supercontinuum pump, which is converted into a phase-stable pulse pair with a controllable femtosecond delay using a birefringent interferometer. The absorption-induced heating from the pump generates a transient thermal lens in the sample, which is detected as a function of delay by an off-resonant 800 nm photothermal probe beam. Fourier transform of the interferometric photothermal response yields a frequency-domain signal corresponding to the sample absorptance spectrum weighted by the pump spectrum. After division by the measured pump spectrum, the reconstructed photothermal spectrum is compared with a direct frequency-domain linear absorption measurement to evaluate the accuracy of the reconstruction. This method combines Fourier-transform broadband excitation with thermal-lens readout, allowing broadband linear absorption spectra to be obtained from pump-induced refractive-index changes rather than from transmitted excitation intensity. We demonstrate the method on phloxine B.

arXiv
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon