Patient satisfaction after implantation of venous port system through different vascular accesses: a pilot study

Objective: to evaluate patient satisfaction with totally implantable venous port systems placed via three different vascular access routes: the internal jugular vein, the axillary vein, and the basilic vein. Materials and Methods. 158 oncology patients requiring long-term chemotherapy were included in this prospective randomized study. Venous ports were implanted using one of three access routes: v. Basilica (n = 50), v. Axillaris (n = 53), or v. Jugularis interna (n = 55). Patient satisfaction with functional and aesthetic outcomes was assessed 6 months after implantation using a standardized questionnaire developed at the N.N. Petrov National Medical Research Center. Results. Overall satisfaction levels were high across all three groups, with median scores ranging from 29 to 30 points, and no significant differences between access types (p = 0,47). There were no statistically significant differences observed for any of the six questionnaire items (p = 0,162–1,000). The rate of late complications was low and comparable between groups (6-7 cases per group; p = 0,935). Postoperative complications were the only one factor that significantly associated with decreased satisfaction. (p = 0,014). An analysis of the impact of postoperative complications on patient satisfaction revealed a statistically significant and strong inverse relationship. Patients who experienced complications (n = 19) had significantly lower satisfaction levels than patients who did not experience complications (n = 139). Conclusion. All three vascular access routes-v. Basilica, v. Axillaris, and v. Jugularis interna-provide similarly high patient satisfaction following venous port implantation. The choice of access route does not influence patient-perceived outcomes. Postoperative complications are the main factor reducing satisfaction, whereas anatomical and technical parameters do not demonstrate a significant effect.

Authors

Institutions

Publication Details

Journal
Zabajkalʹskij medicinskij vestnik
Published
2026-11-26
DOI
https://doi.org/10.52485/19986173_2026_3_59
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Patient satisfaction after implantation of venous port system through different vascular accesses: a pilot study

Valerii V. Subbotin, Andrei A. Klimov, A.A. Malakhova, I.N. Izmailov et al.
Zabajkalʹskij medicinskij vestnik
Central Venous Catheters and Hemodialysis
article

Patient satisfaction after implantation of venous port system through different vascular accesses: a pilot study

Valerii V. Subbotin, Andrei A. Klimov, A.A. Malakhova, I.N. Izmailov, O.I. Nekrasov
article en

Abstract

Objective: to evaluate patient satisfaction with totally implantable venous port systems placed via three different vascular access routes: the internal jugular vein, the axillary vein, and the basilic vein. Materials and Methods. 158 oncology patients requiring long-term chemotherapy were included in this prospective randomized study. Venous ports were implanted using one of three access routes: v. Basilica (n = 50), v. Axillaris (n = 53), or v. Jugularis interna (n = 55). Patient satisfaction with functional and aesthetic outcomes was assessed 6 months after implantation using a standardized questionnaire developed at the N.N. Petrov National Medical Research Center. Results. Overall satisfaction levels were high across all three groups, with median scores ranging from 29 to 30 points, and no significant differences between access types (p = 0,47). There were no statistically significant differences observed for any of the six questionnaire items (p = 0,162–1,000). The rate of late complications was low and comparable between groups (6-7 cases per group; p = 0,935). Postoperative complications were the only one factor that significantly associated with decreased satisfaction. (p = 0,014). An analysis of the impact of postoperative complications on patient satisfaction revealed a statistically significant and strong inverse relationship. Patients who experienced complications (n = 19) had significantly lower satisfaction levels than patients who did not experience complications (n = 139). Conclusion. All three vascular access routes-v. Basilica, v. Axillaris, and v. Jugularis interna-provide similarly high patient satisfaction following venous port implantation. The choice of access route does not influence patient-perceived outcomes. Postoperative complications are the main factor reducing satisfaction, whereas anatomical and technical parameters do not demonstrate a significant effect.

Zabajkalʹskij medicinskij vestnik(3)
Moscow Clinical Scientific Center (RU)
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon