Comparison of electroanatomic mapping-guided versus high-frequency stimulation-guided cardioneuroablation for vasovagal syncope: a systematic review and meta-analysis
When conservative management yields unsatisfactory outcomes in patients with vasovagal syncope (VVS), cardioneuroablation (CNA) serves as a novel therapeutic approach with substantial efficacy in reducing syncopal recurrence. However, despite the availability of various feasible ablation modalities, the comparative efficacy among different strategies remains unclear. Accordingly, we performed a meta-analysis to compare the efficacy of electroanatomic mapping (EAM)-guided versus high-frequency stimulation (HFS)-guided CNA for VVS, with post-procedural syncopal recurrence as the primary endpoint and positive head-up tilt test (HUT) result as the secondary endpoint. We searched the PubMed, Cochrane, and Embase databases from their inception to 15 January 2026. Studies that included both EAM- and HFS-guided CNA were enrolled. Two authors independently evaluated the quality of the included studies using the Newcastle-Ottawa Scale (NOS) and the Agency for Healthcare Research and Quality (AHRQ) tool. Meta-analysis was conducted with Stata 17 software, and a random-effects model was applied when pooling data with high heterogeneity. A total of 5 studies were included, involving 281 patients with VVS who underwent CNA (179 in the EAM group and 102 in the HFS group). Of these, 222 patients (156 in the EAM group and 66 in the HFS group) provided evaluable data for the primary outcome of syncope recurrence and were included in the pooled analysis. Results demonstrated that there was no statistically significant difference in syncopal recurrence rates between patients receiving EAM- and HFS-guided CNA (RR 0.76, 95% CI 0.09–6.74, I 2 = 69.5%, p = 0.808). Exploratory subgroup analyses suggested a possible reduction in syncopal recurrence with EAM-guided CNA among the included European studies, all of which adopted biatrial ablation (RR = 0.06, 95% CI 0.01–0.49, p = 0.008). Furthermore, there was no statistically significant difference in HUT positive rates between the EAM and HFS groups (RR = 0.09, 95% CI 0.00–2.56, I 2 = 81.2%, p = 0.158). While this meta‑analysis found no significant between‑group difference in syncope recurrence, exploratory subgroup analyses hinted at a potential benefit of EAM-guided CNA among the included European studies, all of which adopted biatrial ablation. Given the limited sample size, these findings should be interpreted with caution.
Authors
- Jin Dai (ORCID: https://orcid.org/0000-0002-0111-9009)
- Fu Meiling
- Xiao Wang (ORCID: https://orcid.org/0000-0002-5837-2996)
- Min Zhu (ORCID: https://orcid.org/0000-0003-2605-9791)
- Xinbin Zhou
- Yiduo Sun
- Weizhu Xiong
- Yuangang Qiu
- Xun Chen
- Jiangyue Hu
- Jie Chen
Institutions
- Zhejiang Chinese Medical University (CN)
Publication Details
- Journal
- Scientific Reports
- Published
- 2026-11-26
- DOI
- https://doi.org/10.1038/s41598-026-82141-1
- Primary Topic
- Cardiovascular Syncope and Autonomic Disorders
- Type
- article
- Field-Weighted Citation Impact
- 0.00