Clean-Booth Dynamics: Investigating the Impact of Blower Arrangement and Airspeed on Contamination Control
Particle contamination remains a critical concern in medical and semiconductor industries, especially considering the COVID-19 pandemic, which has heightened focus on clean-booth systems. These booths, equipped with blower systems and high-efficiency filters, play an essential role in maintaining air quality by removing airborne particles. In this study, computational fluid dynamics simulations, using modified Navier–Stokes equations with a k-ε turbulence model coupled with a Lagrangian particle model, were employed to predict the performance of clean booths in controlling particle contamination. The effects of blower arrangement, exit size, and airspeed on particle concentration were evaluated. At an inlet airspeed of 0.4 m/s, the simulated booth-average particle number concentration first reached or fell below the reference threshold of 35,200 particles/m3 in approximately 12 and 30 s for the configurations with 100% and 65% blower coverage, respectively. The alternating-row configuration with 50% coverage did not reach the threshold within the simulated interval. At the common blower face velocity of 0.4 m/s, the configurations had different total supply airflow rates because their active inlet areas differed. The clearance results therefore reflect the combined effects of blower arrangement and total supply airflow. For the fully covered configuration, the booth-average concentration reached the threshold in approximately 7 s at 0.6 m/s and remained above it throughout the simulated interval at 0.1 m/s. These clearance times describe the booth-average concentration and do not establish ISO Class 6 compliance throughout the booth. The model’s accuracy was validated through experimental measurements using a SKY6000 particle counter, showing a maximum deviation of 12.5% in particle concentration at different locations. This study underscores the importance of blower arrangement and airspeed in optimizing clean-booth performance for efficient contamination control.
Authors
- Swami Nath Maurya (ORCID: https://orcid.org/0000-0002-8726-6172)
- Amir Reza Ansari Dezfoli (ORCID: https://orcid.org/0000-0003-2698-7571)
- Yi‐Jen Huang (ORCID: https://orcid.org/0000-0002-8948-6988)
Institutions
- National Chin-Yi University of Technology (TW)
Publication Details
- Journal
- Atmosphere
- Published
- 2026-11-26
- DOI
- https://doi.org/10.3390/atmos17121171
- Primary Topic
- Aerosol Filtration and Electrostatic Precipitation
- Type
- article
- Field-Weighted Citation Impact
- 0.00