Psychometric Evaluation of the Persian Version of the Person-Centered Critical Care Nursing Questionnaire

Background: Person-centered care is recognized as one of the core values in the delivery of high-quality healthcare. Given the importance of this approach in intensive care settings, the translation and psychometric evaluation of a valid instrument for measuring person-centered critical care nursing is essential for the Iranian healthcare system. Objective: This study aimed to translate and psychometrically evaluate the Person-Centered Critical Care Nursing Questionnaire in Persian. Methods: This methodological study was conducted during 2022–2023 among 300 nurses working in intensive care units. The original questionnaire was translated into Persian using the World Health Organization forward-backward translation protocol. Face validity, content validity, construct validity, and reliability were assessed. Construct validity was examined using confirmatory factor analysis. Reliability was evaluated using Cronbach’s alpha coefficient and test-retest stability through the interclass correlation coefficient. Results: Face validity was confirmed after minor revisions to several items. Content validity was assessed qualitatively and confirmed by experts. Confirmatory factor analysis showed an acceptable model fit after deleting Item 4. Fit indices were as follows: χ2/df = 3.56, CFI = 0.92, SRMR = 0.074, and NNFI = 0.89. The RMSEA was 0.09 (90% CI: 0.082–0.11). The overall internal consistency of the questionnaire was acceptable, with a Cronbach’s alpha of 0.81. Test-retest reliability was also satisfactory, with an interclass correlation coefficient of 0.93. Conclusion: The Persian version of the Person-Centered Critical Care Nursing Questionnaire demonstrated acceptable validity and reliability and can be used as an appropriate instrument for assessing person-centered nursing care in intensive care units in Iran.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-26
DOI
https://doi.org/10.21203/rs.3.rs-11537106/v1
Primary Topic
Health Education and Validation
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Psychometric Evaluation of the Persian Version of the Person-Centered Critical Care Nursing Questionnaire

Malihe Sadat Moayed, Yaser Saeid, Abbas Ebadi, Mirakbar Mirebrahimi
Research Square
Health Education and Validation
preprint

Psychometric Evaluation of the Persian Version of the Person-Centered Critical Care Nursing Questionnaire

Malihe Sadat Moayed, Yaser Saeid, Abbas Ebadi, Mirakbar Mirebrahimi
preprint en

Abstract

Background: Person-centered care is recognized as one of the core values in the delivery of high-quality healthcare. Given the importance of this approach in intensive care settings, the translation and psychometric evaluation of a valid instrument for measuring person-centered critical care nursing is essential for the Iranian healthcare system. Objective: This study aimed to translate and psychometrically evaluate the Person-Centered Critical Care Nursing Questionnaire in Persian. Methods: This methodological study was conducted during 2022–2023 among 300 nurses working in intensive care units. The original questionnaire was translated into Persian using the World Health Organization forward-backward translation protocol. Face validity, content validity, construct validity, and reliability were assessed. Construct validity was examined using confirmatory factor analysis. Reliability was evaluated using Cronbach’s alpha coefficient and test-retest stability through the interclass correlation coefficient. Results: Face validity was confirmed after minor revisions to several items. Content validity was assessed qualitatively and confirmed by experts. Confirmatory factor analysis showed an acceptable model fit after deleting Item 4. Fit indices were as follows: χ2/df = 3.56, CFI = 0.92, SRMR = 0.074, and NNFI = 0.89. The RMSEA was 0.09 (90% CI: 0.082–0.11). The overall internal consistency of the questionnaire was acceptable, with a Cronbach’s alpha of 0.81. Test-retest reliability was also satisfactory, with an interclass correlation coefficient of 0.93. Conclusion: The Persian version of the Person-Centered Critical Care Nursing Questionnaire demonstrated acceptable validity and reliability and can be used as an appropriate instrument for assessing person-centered nursing care in intensive care units in Iran.

Research Square
Baqiyatallah University of Medical Sciences (IR)
Health Education and Validation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Psychometric Evaluation of the Persian Version of the Person-Centered Critical Care Nursing Questionnaire — Malihe Sadat Moayed, Yaser Saeid, et al. · Research Square (2026) | TGRS Research Map | TGRS