MT-RWKV: A Lightweight VRWKV-Based Multi-Task Framework for Breast Ultrasound Lesion Localization and Image-Level Diagnosis

Background/Objectives: Breast ultrasound lesion segmentation and image-level diagnostic classification are closely related tasks. However, existing multi-task approaches often rely mainly on shared encoded features, without explicitly exploiting lesion localization information for classification, and may suffer from gradient competition between segmentation and classification objectives. This study proposes MT-RWKV, a lightweight multi-task framework for joint breast ultrasound lesion segmentation and three-class image-level classification. Methods: MT-RWKV uses a shared Vision-RWKV backbone, a progressive segmentation decoder with a high-resolution edge bypass, and Residual Mask Gating for segmentation-guided classification. A mask-path gradient scaler controls classification feedback to the segmentation branch. Performance on BUSI and BUS-UCLM was summarized using five-fold cross-validation. Thresholds were selected on validation data and fixed for test evaluation. Additional experiments examined gradient scaling, multi-task optimization, mask correction, and computational efficiency. Results: MT-RWKV achieved a Dice score of 83.09 ± 0.75%, classification accuracy of 94.87 ± 0.45%, and AUC of 98.12 ± 0.18% on BUSI. On BUS-UCLM, Dice was 94.53 ± 0.45%, accuracy was 97.07 ± 0.67%, and AUC was 98.06 ± 0.43%. Values represent means ± standard deviations across five folds. The model contained 6.98 million parameters and required 12.46 GFLOPs, with an inference time of 9.83 ms per image in the common efficiency benchmark. Conclusions: Explicit segmentation guidance and controlled mask-path feedback supported joint lesion localization and three-class classification on two public breast ultrasound benchmarks. MT-RWKV combined favorable predictive performance with a compact shared architecture.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-11-26
DOI
https://doi.org/10.3390/diagnostics16234000
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

MT-RWKV: A Lightweight VRWKV-Based Multi-Task Framework for Breast Ultrasound Lesion Localization and Image-Level Diagnosis

Danchen Yang, Dangguo Shao, Sanli Yi, Lei Ma
Diagnostics
AI in cancer detection
article

MT-RWKV: A Lightweight VRWKV-Based Multi-Task Framework for Breast Ultrasound Lesion Localization and Image-Level Diagnosis

Danchen Yang, Dangguo Shao, Sanli Yi, Lei Ma
article en

Abstract

Background/Objectives: Breast ultrasound lesion segmentation and image-level diagnostic classification are closely related tasks. However, existing multi-task approaches often rely mainly on shared encoded features, without explicitly exploiting lesion localization information for classification, and may suffer from gradient competition between segmentation and classification objectives. This study proposes MT-RWKV, a lightweight multi-task framework for joint breast ultrasound lesion segmentation and three-class image-level classification. Methods: MT-RWKV uses a shared Vision-RWKV backbone, a progressive segmentation decoder with a high-resolution edge bypass, and Residual Mask Gating for segmentation-guided classification. A mask-path gradient scaler controls classification feedback to the segmentation branch. Performance on BUSI and BUS-UCLM was summarized using five-fold cross-validation. Thresholds were selected on validation data and fixed for test evaluation. Additional experiments examined gradient scaling, multi-task optimization, mask correction, and computational efficiency. Results: MT-RWKV achieved a Dice score of 83.09 ± 0.75%, classification accuracy of 94.87 ± 0.45%, and AUC of 98.12 ± 0.18% on BUSI. On BUS-UCLM, Dice was 94.53 ± 0.45%, accuracy was 97.07 ± 0.67%, and AUC was 98.06 ± 0.43%. Values represent means ± standard deviations across five folds. The model contained 6.98 million parameters and required 12.46 GFLOPs, with an inference time of 9.83 ms per image in the common efficiency benchmark. Conclusions: Explicit segmentation guidance and controlled mask-path feedback supported joint lesion localization and three-class classification on two public breast ultrasound benchmarks. MT-RWKV combined favorable predictive performance with a compact shared architecture.

DiagnosticsVol. 16(23)
Kunming University of Science and Technology (CN)
AI in cancer detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon