La Paz 220 kV tubular backbone: 20 × 35 m poles, ACSR 400, 250 m spans

Short answer: the SOLARTODO LIMITED La Paz configuration guide sizes about 20 tapered steel tubular poles of 35 m for a 220 kV single-circuit backbone of roughly 5 km, at 250 m spans. Each pole is hot-dip galvanized Q345, about 21 t. The conductor is ACSR 400 at 1,520 kg/km with a maximum tension of 110 kN, 6 m phase spacing and 2.5 m insulator strings. The wind basis is Class 2 at 30 m/s, and the standards basis is IEC 60826, GB 50545 and DL/T 5092. The city sits at about 3,625 m, which drives the erection plan as much as the steel does. La Paz 35 m 220 kV tubular pole line — Figures the page fixes Line: about 20 poles, 220 kV single circuit, about 5 km, 250 m spans Pole: 35 m tapered tubular, Q345 hot-dip galvanized, about 21 t (size class 35–55 m, 15–35 t) Conductor: ACSR 400, 1,520 kg/km, maximum tension 110 kN Geometry: 6 m phase spacing, 2.5 m insulator strings Wind: Class 2, 30 m/s basic design wind for the stated package Standards basis: IEC 60826, GB 50545, DL/T 5092 Site: about 3,625 m altitude, 14.6 °C average; the page notes altitude in the metro area from 420 m to 6,438 m La Paz 35 m 220 kV tubular pole line — What to confirm before ordering Limits: 250 m spans are shorter than the 350–450 m generic 220 kV range, because the page assumes a constrained Andean urban basin. Where the route opens up, longer spans change the pole count, tension and foundation loads, so the 20-pole figure belongs to this corridor only. The page recommends 30 m/s and asks for local wind amplification at ridges, valleys and escarpments to be reviewed. In a basin city that review is not optional. IEC 60826 gives reliability-based loading for lines at 45 kV and above; GB 50545 and DL/T 5092 are design codes. Naming them is a basis, not a completed calculation. Altitude affects people and machines: crane capacity, access road gradient and worker oxygen management are listed as erection constraints. Insulation coordination at high altitude is also a check for the line designer; the 2.5 m string length is the page's value, not an altitude-corrected result. Page: https://solartodo.com/solutions/la-paz-power-tower-20-unit-35m-220kv-single-circuit La Paz 35 m 220 kV tubular pole line — Acceptance questions Can 250 m spans be reused elsewhere? Only on similar constrained routes. Open terrain usually allows longer spans and fewer poles. Is the insulator length corrected for altitude? The page gives 2.5 m; altitude correction is a separate design check. SOLARTODO LIMITED Headquarters: Gaoyou, Yangzhou, Jiangsu, China Management references: ISO 9001:2015, ISO 14001:2015, ISO 45001:2018 This note: La Paz, 20 × 35 m tubular poles, 220 kV, ACSR 400, 110 kN, 250 m spans, IEC 60826, GB 50545, DL/T 5092 Figures attached to this record: EN-PT-C137_scene.jpg, EN-PT-C137_spec.jpg, EN-PT-C137_cards.jpg.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-26
DOI
https://doi.org/10.5281/zenodo.24562020
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

La Paz 220 kV tubular backbone: 20 × 35 m poles, ACSR 400, 250 m spans

SOLARTODO LIMITED
Zenodo (CERN European Organization for Nuclear Research)
High-Voltage Power Transmission Systems
article

La Paz 220 kV tubular backbone: 20 × 35 m poles, ACSR 400, 250 m spans

SOLARTODO LIMITED
article en

Abstract

Short answer: the SOLARTODO LIMITED La Paz configuration guide sizes about 20 tapered steel tubular poles of 35 m for a 220 kV single-circuit backbone of roughly 5 km, at 250 m spans. Each pole is hot-dip galvanized Q345, about 21 t. The conductor is ACSR 400 at 1,520 kg/km with a maximum tension of 110 kN, 6 m phase spacing and 2.5 m insulator strings. The wind basis is Class 2 at 30 m/s, and the standards basis is IEC 60826, GB 50545 and DL/T 5092. The city sits at about 3,625 m, which drives the erection plan as much as the steel does. La Paz 35 m 220 kV tubular pole line — Figures the page fixes Line: about 20 poles, 220 kV single circuit, about 5 km, 250 m spans Pole: 35 m tapered tubular, Q345 hot-dip galvanized, about 21 t (size class 35–55 m, 15–35 t) Conductor: ACSR 400, 1,520 kg/km, maximum tension 110 kN Geometry: 6 m phase spacing, 2.5 m insulator strings Wind: Class 2, 30 m/s basic design wind for the stated package Standards basis: IEC 60826, GB 50545, DL/T 5092 Site: about 3,625 m altitude, 14.6 °C average; the page notes altitude in the metro area from 420 m to 6,438 m La Paz 35 m 220 kV tubular pole line — What to confirm before ordering Limits: 250 m spans are shorter than the 350–450 m generic 220 kV range, because the page assumes a constrained Andean urban basin. Where the route opens up, longer spans change the pole count, tension and foundation loads, so the 20-pole figure belongs to this corridor only. The page recommends 30 m/s and asks for local wind amplification at ridges, valleys and escarpments to be reviewed. In a basin city that review is not optional. IEC 60826 gives reliability-based loading for lines at 45 kV and above; GB 50545 and DL/T 5092 are design codes. Naming them is a basis, not a completed calculation. Altitude affects people and machines: crane capacity, access road gradient and worker oxygen management are listed as erection constraints. Insulation coordination at high altitude is also a check for the line designer; the 2.5 m string length is the page's value, not an altitude-corrected result. Page: https://solartodo.com/solutions/la-paz-power-tower-20-unit-35m-220kv-single-circuit La Paz 35 m 220 kV tubular pole line — Acceptance questions Can 250 m spans be reused elsewhere? Only on similar constrained routes. Open terrain usually allows longer spans and fewer poles. Is the insulator length corrected for altitude? The page gives 2.5 m; altitude correction is a separate design check. SOLARTODO LIMITED Headquarters: Gaoyou, Yangzhou, Jiangsu, China Management references: ISO 9001:2015, ISO 14001:2015, ISO 45001:2018 This note: La Paz, 20 × 35 m tubular poles, 220 kV, ACSR 400, 110 kN, 250 m spans, IEC 60826, GB 50545, DL/T 5092 Figures attached to this record: EN-PT-C137_scene.jpg, EN-PT-C137_spec.jpg, EN-PT-C137_cards.jpg.

Zenodo (CERN European Organization for Nuclear Research)
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon