Three-Dimensional RANS Simulation of the Flow Field and Bed Shear Stress Around a Bridge Pier Combined with Abutments, with Collars and a Vertical Flow Deflector
Purpose Local scour at a bridge pier that shares a contracted section with abutments is driven by a flow field that experiments alone cannot describe. This study uses numerical simulation to explain laboratory measurements of scour around a rectangular pier (3 cm × 20 cm) placed between two equal abutments in a 40 cm wide flume, without protection and with bed-level collars and a vertical plate flow deflector. Methods The steady Reynolds-averaged Navier–Stokes (RANS) equations were solved with the open-source code OpenFOAM (Open Source Field Operation and Manipulation), using the k –ω shear-stress transport (SST) turbulence model and Spalding’s wall function. The model was validated against published velocity and bed-shear measurements in an equilibrium scour hole around a cylinder, and the numerical uncertainty was quantified with the grid convergence index (GCI) on three meshes. Flat-bed, scoured-bed and collar-in-hole cases were simulated at Froude numbers of 0.19–0.53. Results The model reproduced the peak downflow at the cylinder face (− 0.59 U versus − 0.60 U measured), its elevation and radial decay, and the onset of reversed bed shear. The approach-flow shear and the bed shear beyond about one pier width from the structures were mesh-independent (GCI < 5%), whereas the peak at the sharp pier corners was not. Bed shear was amplified about five times at the upstream corners, and the downflow at the pier nose increased from 0.41–0.43 V on a flat bed to 0.82 V in the equilibrium scour hole. Collars of width B c / b ≥ 4 reduced the peak shear on the exposed bed to about 2.5–2.8 times the approach value, and a collar inside the scour hole halved the downflow reaching the hole bottom and lowered the bottom shear from 0.93τ c to 0.41τ c. The computed excess shear explained the measured relative scour depth for 27 conditions (r = 0.95, R 2 = 0.89). A vertical plate deflector reduced the peak downflow by about 20%, and a plate height d / b ≈ 0.33 gave the lowest shear ahead of the nose. Conclusions Collars and deflectors act mainly by intercepting the downflow at the pier nose; a collar of about 4 b covers the strongly amplified region, and a deflector of height 0.33 b agrees with the experimental optimum. Peak values at sharp corners are mesh-dependent and are interpreted qualitatively, and the results are limited to fixed beds and a rigid water surface.
Authors
- Ahmed Shawky
Institutions
- Benha University (EG)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-26
- DOI
- https://doi.org/10.21203/rs.3.rs-11541640/v1
- Primary Topic
- Hydraulic flow and structures
- Type
- preprint