Real-time recurrent laryngeal nerve identification in endoscopic thyroid surgery using YOLO-based video analysis

Precise identification of the recurrent laryngeal nerve (RLN) remains challenging in endoscopic thyroid surgery, with injury rates up to 4.7%. We developed a real-time YOLO-based deep learning system to assist intraoperative RLN identification during endoscopic thyroid surgery. Surgical videos from 63 patients yielded 3,826 annotated frames. Frames from 54 patients were used for training and validation, while frames from 9 independent patients formed the test-candidate pool, from which a standardized 135-frame image-level test set was constructed. Four YOLO-based models were evaluated, and the optimal architecture, YOLOv11 Instance Segment-Accurate, was selected using validation-set performance and additionally assessed using sampled-frame video segments from multiple institutions. For model selection on the validation dataset, this model achieved a mean average precision (mAP) of 58.8%, with validation precision and recall of 70.9% and 48.3%, respectively. On the independent 135-frame image-level test set, the model achieved a precision of 91.7%, recall of 85.6%, F1-score of 88.5%, and overall accuracy of 85.2%. These metrics represent different evaluation settings: mAP reflects spatial localization/segmentation performance, whereas the test-set precision, recall, F1-score, and accuracy reflect binary image-level RLN identification. The model processed each frame in 0.012 s, supporting the technical feasibility of real-time inference. In a limited 34-second live-setting video segment, the system sustained 30 frames per second on local hardware. These findings support the feasibility of YOLO-based video analysis as a potential intraoperative decision-support approach for RLN identification, warranting further prospective clinical evaluation.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-26
DOI
https://doi.org/10.1038/s41598-026-82390-0
Primary Topic
Thyroid and Parathyroid Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Real-time recurrent laryngeal nerve identification in endoscopic thyroid surgery using YOLO-based video analysis

Xiaoyao Tao, Busheng Tong, Yehai Liu, Dezhi Yu et al.
Scientific Reports
Thyroid and Parathyroid Surgery
article

Real-time recurrent laryngeal nerve identification in endoscopic thyroid surgery using YOLO-based video analysis

Xiaoyao Tao, Busheng Tong, Yehai Liu, Dezhi Yu, Yi Zhao, Xu Zhao
article en

Abstract

Precise identification of the recurrent laryngeal nerve (RLN) remains challenging in endoscopic thyroid surgery, with injury rates up to 4.7%. We developed a real-time YOLO-based deep learning system to assist intraoperative RLN identification during endoscopic thyroid surgery. Surgical videos from 63 patients yielded 3,826 annotated frames. Frames from 54 patients were used for training and validation, while frames from 9 independent patients formed the test-candidate pool, from which a standardized 135-frame image-level test set was constructed. Four YOLO-based models were evaluated, and the optimal architecture, YOLOv11 Instance Segment-Accurate, was selected using validation-set performance and additionally assessed using sampled-frame video segments from multiple institutions. For model selection on the validation dataset, this model achieved a mean average precision (mAP) of 58.8%, with validation precision and recall of 70.9% and 48.3%, respectively. On the independent 135-frame image-level test set, the model achieved a precision of 91.7%, recall of 85.6%, F1-score of 88.5%, and overall accuracy of 85.2%. These metrics represent different evaluation settings: mAP reflects spatial localization/segmentation performance, whereas the test-set precision, recall, F1-score, and accuracy reflect binary image-level RLN identification. The model processed each frame in 0.012 s, supporting the technical feasibility of real-time inference. In a limited 34-second live-setting video segment, the system sustained 30 frames per second on local hardware. These findings support the feasibility of YOLO-based video analysis as a potential intraoperative decision-support approach for RLN identification, warranting further prospective clinical evaluation.

Scientific Reports
Chinese Academy of Sciences (CN), Institute of Automation (CN), First Affiliated Hospital of Anhui Medical University (CN)
Thyroid and Parathyroid Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon