Critical-Point-Anchored Hybrid Helmholtz Equations of State: Calibration Trade-Offs and Limits for Eight Reference Fluids

A two-parameter cubic equation of state (EoS) fixes its critical compressibility factor: Peng–Robinson (PR) with constants fitted to saturation data reaches only the surface Zc=0.3074 and misplaces the critical volume of every real fluid. On a per-fluid basis, we calibrate a hybrid residual Helmholtz energy in which PR is an exact limit and a small neural correction is trained with the classical critical conditions as an anchor. One documented run of 276 units covered three synthetic cubic truths, held-out temperatures, eight fluids described by reference EoS of the National Institute of Standards and Technology (NIST), a sweep of the anchor weight and a noise study. For the eight fluids the anchor reduced the mean absolute relative error (MARE) in Vc from 14.74% (refitted PR) to 0.32% and the root mean square relative error (RMSRE) in saturation pressure from 5.51% to 1.05%; against the unanchored hybrid, whose RMSRE was 0.46%, the cost was 0.59 percentage points, within a one-point margin for seven fluids. PR with reference constants kept a lower pressure RMSRE (0.83%) and a liquid density RMSRE 20 times larger. Without the anchor the inferred Vc varied by up to 22% across initialisations. A revision run harmonised the ammonia anchor with the EoS behind its data, which removed a 3.7% offset in Vc without lowering the pressure cost, and traced low-temperature solver failures to the solver. Learned critical isotherms are flatter in the pressure–density plane; dilute and supercritical gas states are not constrained (up to 41% pressure error at 2Tc), so the models apply to saturated states only. Prediction for unseen molecules is not tested.

Authors

Institutions

Publication Details

Journal
International Journal of Molecular Sciences
Published
2026-11-26
DOI
https://doi.org/10.3390/ijms272310720
Primary Topic
Phase Equilibria and Thermodynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Critical-Point-Anchored Hybrid Helmholtz Equations of State: Calibration Trade-Offs and Limits for Eight Reference Fluids

José García, Vanesa Bazán, Pedro A. Robles, Luis Rios-Colque et al.
International Journal of Molecular Sciences
Phase Equilibria and Thermodynamics
article

Critical-Point-Anchored Hybrid Helmholtz Equations of State: Calibration Trade-Offs and Limits for Eight Reference Fluids

José García, Vanesa Bazán, Pedro A. Robles, Luis Rios-Colque, Luis Rojas
article en

Abstract

A two-parameter cubic equation of state (EoS) fixes its critical compressibility factor: Peng–Robinson (PR) with constants fitted to saturation data reaches only the surface Zc=0.3074 and misplaces the critical volume of every real fluid. On a per-fluid basis, we calibrate a hybrid residual Helmholtz energy in which PR is an exact limit and a small neural correction is trained with the classical critical conditions as an anchor. One documented run of 276 units covered three synthetic cubic truths, held-out temperatures, eight fluids described by reference EoS of the National Institute of Standards and Technology (NIST), a sweep of the anchor weight and a noise study. For the eight fluids the anchor reduced the mean absolute relative error (MARE) in Vc from 14.74% (refitted PR) to 0.32% and the root mean square relative error (RMSRE) in saturation pressure from 5.51% to 1.05%; against the unanchored hybrid, whose RMSRE was 0.46%, the cost was 0.59 percentage points, within a one-point margin for seven fluids. PR with reference constants kept a lower pressure RMSRE (0.83%) and a liquid density RMSRE 20 times larger. Without the anchor the inferred Vc varied by up to 22% across initialisations. A revision run harmonised the ammonia anchor with the EoS behind its data, which removed a 3.7% offset in Vc without lowering the pressure cost, and traced low-temperature solver failures to the solver. Learned critical isotherms are flatter in the pressure–density plane; dilute and supercritical gas states are not constrained (up to 41% pressure error at 2Tc), so the models apply to saturated states only. Prediction for unseen molecules is not tested.

International Journal of Molecular SciencesVol. 27(23)
Pontificia Universidad Católica de Valparaíso (CL), Consejo Nacional de Investigaciones Científicas y Técnicas (AR), National University of San Juan (AR)
Phase Equilibria and Thermodynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon