Equation-Informed XGBoost Residual Learning for Axial Capacity Prediction of Seawater Sea-Sand Concrete-Filled Double-Skin CFRP-Steel Composite Tube Columns

Seawater sea-sand concrete-filled double-skin CFRP–steel composite tube (SFDCT) columns combine a hollow section with corrosion-resistant confinement, but their axial capacity is governed by coupled geometric and material parameters. The framework retains a published axial-capacity equation as a multiplicative physical baseline and uses XGBoost to learn the logarithmic correction between the finite element and theoretical capacities. An experimentally validated three-dimensional finite element model is used to construct an 819-case parametric database. All cases are retained for finite element analysis, while 738 cases satisfying 20 ≤ Do/to ≤ 100 and 15 ≤ Di/ti ≤ 55 are used to compare five prediction schemes: the original equation (M0), a training-set scalar correction (M1), direct XGBoost prediction (M2), theory-augmented direct XGBoost prediction (M2-T) and physics-guided XGBoost residual learning (M3). M3 learns the logarithmic ratio between finite element and theoretical capacities and reconstructs the final capacity through a multiplicative correction. Performance is evaluated using a random 80/20 split and five-fold cross-validation grouped by the inner- and outer-tube geometries. Evaluated against FE capacities under geometry-grouped validation, M2-T achieves a pooled out-of-fold R2 of 0.9777 and MAPE of 2.34%, while M3 gives 0.9741 and 2.64%, respectively, with a higher P10 of 99.32% versus 97.97% for M2-T. SHAP analysis indicates that the nominal concrete contribution, nominal outer-steel contribution, and outer diameter govern most of the residual correction. The comparisons demonstrate the value of incorporating theoretical capacity in prediction for withheld geometric combinations under the evaluated grouped-validation scheme.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-11-26
DOI
https://doi.org/10.3390/buildings16234750
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Equation-Informed XGBoost Residual Learning for Axial Capacity Prediction of Seawater Sea-Sand Concrete-Filled Double-Skin CFRP-Steel Composite Tube Columns

Yirui Zhang, Zilong Ge, Sunchao Ge, Xinyang Yin et al.
Buildings
Structural Load-Bearing Analysis
article

Equation-Informed XGBoost Residual Learning for Axial Capacity Prediction of Seawater Sea-Sand Concrete-Filled Double-Skin CFRP-Steel Composite Tube Columns

Yirui Zhang, Zilong Ge, Sunchao Ge, Xinyang Yin, Xing Wei, Haoyu Zeng
article en

Abstract

Seawater sea-sand concrete-filled double-skin CFRP–steel composite tube (SFDCT) columns combine a hollow section with corrosion-resistant confinement, but their axial capacity is governed by coupled geometric and material parameters. The framework retains a published axial-capacity equation as a multiplicative physical baseline and uses XGBoost to learn the logarithmic correction between the finite element and theoretical capacities. An experimentally validated three-dimensional finite element model is used to construct an 819-case parametric database. All cases are retained for finite element analysis, while 738 cases satisfying 20 ≤ Do/to ≤ 100 and 15 ≤ Di/ti ≤ 55 are used to compare five prediction schemes: the original equation (M0), a training-set scalar correction (M1), direct XGBoost prediction (M2), theory-augmented direct XGBoost prediction (M2-T) and physics-guided XGBoost residual learning (M3). M3 learns the logarithmic ratio between finite element and theoretical capacities and reconstructs the final capacity through a multiplicative correction. Performance is evaluated using a random 80/20 split and five-fold cross-validation grouped by the inner- and outer-tube geometries. Evaluated against FE capacities under geometry-grouped validation, M2-T achieves a pooled out-of-fold R2 of 0.9777 and MAPE of 2.34%, while M3 gives 0.9741 and 2.64%, respectively, with a higher P10 of 99.32% versus 97.97% for M2-T. SHAP analysis indicates that the nominal concrete contribution, nominal outer-steel contribution, and outer diameter govern most of the residual correction. The comparisons demonstrate the value of incorporating theoretical capacity in prediction for withheld geometric combinations under the evaluated grouped-validation scheme.

BuildingsVol. 16(23)
Nanjing Forestry University (CN)
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon