Rapid and Point-of-Care Detection of Alpha-Fetoprotein for Hepatocellular Carcinoma Surveillance and Management

Alpha-fetoprotein (AFP) measurement complements ultrasonography in hepatocellular carcinoma (HCC) surveillance and is also used for post-treatment follow-up. Current methods provide quantitative results but generally require serum or plasma separation and automated analyzers. Rapid and point-of-care testing (POCT) may reduce dependence on central laboratories and provide results during the same clinical visit. However, most reported rapid assays measure total AFP alone and focus on lowering the limit of detection, while broad-range quantification, complete sample-to-result procedures, AFP-L3% calculation, and separate PIVKA-II measurement are neglected. This review summarizes the clinical and technical requirements for rapid AFP testing and discusses recent lateral-flow, microfluidic, electrochemical, and optical methods. These methods are compared in terms of specimen type, reported assay time, quantitative range, readout, and biomarker output. Future development should focus on traceable, broad-range AFP quantification directly from whole blood and on longitudinal measurement of total AFP, AFP-L3%, and PIVKA-II to support HCC surveillance.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-11-26
DOI
https://doi.org/10.3390/bios16120689
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Rapid and Point-of-Care Detection of Alpha-Fetoprotein for Hepatocellular Carcinoma Surveillance and Management

周琴, Rui Wang, Jun Hu, Haipeng Zhu
Biosensors
Biosensors and Analytical Detection
article

Rapid and Point-of-Care Detection of Alpha-Fetoprotein for Hepatocellular Carcinoma Surveillance and Management

周琴, Rui Wang, Jun Hu, Haipeng Zhu
article en

Abstract

Alpha-fetoprotein (AFP) measurement complements ultrasonography in hepatocellular carcinoma (HCC) surveillance and is also used for post-treatment follow-up. Current methods provide quantitative results but generally require serum or plasma separation and automated analyzers. Rapid and point-of-care testing (POCT) may reduce dependence on central laboratories and provide results during the same clinical visit. However, most reported rapid assays measure total AFP alone and focus on lowering the limit of detection, while broad-range quantification, complete sample-to-result procedures, AFP-L3% calculation, and separate PIVKA-II measurement are neglected. This review summarizes the clinical and technical requirements for rapid AFP testing and discusses recent lateral-flow, microfluidic, electrochemical, and optical methods. These methods are compared in terms of specimen type, reported assay time, quantitative range, readout, and biomarker output. Future development should focus on traceable, broad-range AFP quantification directly from whole blood and on longitudinal measurement of total AFP, AFP-L3%, and PIVKA-II to support HCC surveillance.

BiosensorsVol. 16(12)
Karamay Central Hospital (CN), Southeast University (CN)
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon