Genetic Algorithm-Based Optimization of Inverter Control Parameters for Grid-Connected Battery Energy Storage Systems

Background: Grid-connected battery energy storage systems (BESS) require current control that balances harmonic distortion and transient response across changing operating conditions. Aims: This study assessed whether genetic algorithm (GA) tuning of the dq-axis proportional–integral (PI) gains could improve inverter performance relative to conventional tuning. Methods: A 100 kW three-phase LCL-filtered inverter was modeled in MATLAB. Four PI gains were optimized on a combined active- and reactive-power step using a normalized objective comprising total harmonic distortion (THD), settling time, overshoot, and tracking error, with a constraint penalty. The best gains were evaluated across six scenarios (ten test cases); repeatability was assessed using 30 independent GA seeds. Two scenarios were cross-checked using a PWM voltage-source model in Simulink/Simscape Electrical. Results: At nominal conditions, THD decreased from 2.30% to 1.94%, settling time from 5.0 to 3.6 ms, and overshoot from 10.4% to 5.43% in the averaged model. THD decreased in all ten reported test cases, whereas settling time and overshoot improved in nine. However, during charge/discharge reversal, settling time increased from 4.2 to 24.7 ms and overshoot increased from 25.6% to 43.4%, revealing a substantial trade-off between harmonic reduction and transient performance. The Simscape cross-check reproduced the direction of THD and overshoot improvements but did not confirm the settling-time benefit. Conclusion: GA tuning improved current quality and most transient responses in the simulated system, but single-scenario tuning did not ensure satisfactory bidirectional transitions. Multi-scenario optimization and physical validation are needed before deployment.

Authors

Institutions

Publication Details

Journal
Journal of Renewable Energy and Smart Device
Published
2026-11-26
DOI
https://doi.org/10.66314/joresd.v4i2.1829
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Genetic Algorithm-Based Optimization of Inverter Control Parameters for Grid-Connected Battery Energy Storage Systems

Priyadi Hartoko, Erpan Sahiri
Journal of Renewable Energy and Smart Device
Microgrid Control and Optimization
article

Genetic Algorithm-Based Optimization of Inverter Control Parameters for Grid-Connected Battery Energy Storage Systems

Priyadi Hartoko, Erpan Sahiri
article en

Abstract

Background: Grid-connected battery energy storage systems (BESS) require current control that balances harmonic distortion and transient response across changing operating conditions. Aims: This study assessed whether genetic algorithm (GA) tuning of the dq-axis proportional–integral (PI) gains could improve inverter performance relative to conventional tuning. Methods: A 100 kW three-phase LCL-filtered inverter was modeled in MATLAB. Four PI gains were optimized on a combined active- and reactive-power step using a normalized objective comprising total harmonic distortion (THD), settling time, overshoot, and tracking error, with a constraint penalty. The best gains were evaluated across six scenarios (ten test cases); repeatability was assessed using 30 independent GA seeds. Two scenarios were cross-checked using a PWM voltage-source model in Simulink/Simscape Electrical. Results: At nominal conditions, THD decreased from 2.30% to 1.94%, settling time from 5.0 to 3.6 ms, and overshoot from 10.4% to 5.43% in the averaged model. THD decreased in all ten reported test cases, whereas settling time and overshoot improved in nine. However, during charge/discharge reversal, settling time increased from 4.2 to 24.7 ms and overshoot increased from 25.6% to 43.4%, revealing a substantial trade-off between harmonic reduction and transient performance. The Simscape cross-check reproduced the direction of THD and overshoot improvements but did not confirm the settling-time benefit. Conclusion: GA tuning improved current quality and most transient responses in the simulated system, but single-scenario tuning did not ensure satisfactory bidirectional transitions. Multi-scenario optimization and physical validation are needed before deployment.

Journal of Renewable Energy and Smart Device
Sekolah Tinggi Teknologi Angkatan Laut (ID)
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon