Effectiveness of Lean Healthcare in Reducing Complete Blood Count Turnaround Time for Emergency Department Patients
Turnaround time is a core indicator of clinical laboratory performance, especially for complete blood count examinations supporting urgent decisions in the emergency department. This study examined the effectiveness of a lean healthcare intervention in reducing complete blood count turnaround time for emergency department patients, using an action-research design that combined qualitative and quantitative methods. Value stream mapping traced the eight-stage examination flow and measured cycle time, waiting time, and lead time before and after the intervention; in-depth interviews and focus group discussions were conducted with five informants. Total lead time fell from 62.10 minutes before the intervention to 52.49 minutes afterward, a reduction of 9.61 minutes (15.47%), driven mainly by a drop in non-value-added time from 27.82 to 22.86 minutes. The value-added share rose from 52% to 55%. The specimen-preparation stage improved the most, while the analytical stage remained the largest single contributor to lead time. Because the design relied on a single-site, pre-post comparison without a control group or formal significance testing, the findings point to operational improvement rather than a strictly proven causal effect.
Authors
- Muh Agung Prayoga
- Sri Sundari
Publication Details
- Journal
- Jurnal Ilmiah Manajemen Kesatuan
- Published
- 2026-11-25
- DOI
- https://doi.org/10.37641/jimkes.v14i6.5704
- Primary Topic
- Clinical Laboratory Practices and Quality Control
- Type
- article
- Field-Weighted Citation Impact
- 0.00