Fundamental study of a heat-resistant self-powered gamma-ray detector
Self-powered gamma-ray detectors (SPGDs) are promising for monitoring nuclear reactor cores. Since they require no high-voltage supply, they mitigate surge-induced electrical failures and remain applicable even under accident scenarios involving hydrogen generation. In this work, we propose a heat-resistant SPGD designed to reduce neutron-induced reactions in the emitter and measure gamma rays in high-temperature environments. We fabricated a prototype using a lead–bismuth (Pb–Bi) alloy emitter enclosed in an Al2O3 case. Continuous measurements showed constant sensitivity in both solid and molten states, with an increase near the 125°C melting point. The SPGD current exhibited excellent linearity (R2 > 0.99) with dose rate at both room temperature and 300°C. The measured sensitivity at 300°C was 2.2 times that at room temperature, although the origin of this difference could not be determined from the present experiment. Although expansion space in the emitter case caused molten metal separation and 10% sensitivity fluctuations, this can be resolved by optimizing the case volume and electrode geometry. These results demonstrate the feasibility of the proposed SPGD concept for stable operation up to 300°C without liquid-metal leakage, providing a robust solution for gamma-ray monitoring in harsh reactor environments.
Authors
- Y. Murakami
- K. Okada
- A. Fushimi
Institutions
- Hitachi (Japan) (JP)
Publication Details
- Journal
- Journal of Nuclear Science and Technology
- Published
- 2026-11-25
- DOI
- https://doi.org/10.1080/00223131.2026.2766291
- Primary Topic
- Radiation Detection and Scintillator Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00