P–M INTERACTION ANALYSIS OF ECCENTRICALLY LOADED REINFORCED CONCRETE COLUMNS STRENGTHENED WITH CARBON FIBER REINFORCED POLYMER (CFRP) COMPOSITE MATERIALS

This paper investigates the structural efficiency of strengthening eccentrically loaded reinforced concrete columns subjected to combined axial compression and bending moment using carbon fiber-reinforced polymer (CFRP) composite materials. A B20-grade concrete column with a rectangular cross-section of 300×450 mm, a corner rounding radius of r = 25 mm, and 6Ø20 mm (A400 grade) longitudinal reinforcement was analyzed. Based on the plane-sections hypothesis and the ACI 440.2R-17 design methodology, complete P–M interaction diagrams were constructed for three structural configurations: an unstrengthened control column (C0), a column confined solely with two layers of transverse CFRP wrapping (C1), and a hybrid system combining longitudinal CFRP laminates with transverse CFRP wrapping (C2). Analytical results across eccentricity levels (e0 = 0, 50, 120, and 220 mm) reveal that under concentric and low-eccentricity loading (e0 ≤ 50 mm), transverse wrapping increases axial load capacity by 2.7–2.9%, whereas under high eccentricity (e0 = 220 mm), the hybrid C2 scheme enhances ultimate load-carrying capacity by 9.4% and bending moment resistance up to 260.0 kN·m, providing more than twice the gain of transverse wrapping alone.

Authors

Institutions

Publication Details

Published
2026-11-26
DOI
https://doi.org/10.70413/edutech-v01-i02-a11684
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

P–M INTERACTION ANALYSIS OF ECCENTRICALLY LOADED REINFORCED CONCRETE COLUMNS STRENGTHENED WITH CARBON FIBER REINFORCED POLYMER (CFRP) COMPOSITE MATERIALS

Qurbonov Jahongir Komiljon o'g'li
Structural Behavior of Reinforced Concrete
article

P–M INTERACTION ANALYSIS OF ECCENTRICALLY LOADED REINFORCED CONCRETE COLUMNS STRENGTHENED WITH CARBON FIBER REINFORCED POLYMER (CFRP) COMPOSITE MATERIALS

Qurbonov Jahongir Komiljon o'g'li
article en

Abstract

This paper investigates the structural efficiency of strengthening eccentrically loaded reinforced concrete columns subjected to combined axial compression and bending moment using carbon fiber-reinforced polymer (CFRP) composite materials. A B20-grade concrete column with a rectangular cross-section of 300×450 mm, a corner rounding radius of r = 25 mm, and 6Ø20 mm (A400 grade) longitudinal reinforcement was analyzed. Based on the plane-sections hypothesis and the ACI 440.2R-17 design methodology, complete P–M interaction diagrams were constructed for three structural configurations: an unstrengthened control column (C0), a column confined solely with two layers of transverse CFRP wrapping (C1), and a hybrid system combining longitudinal CFRP laminates with transverse CFRP wrapping (C2). Analytical results across eccentricity levels (e0 = 0, 50, 120, and 220 mm) reveal that under concentric and low-eccentricity loading (e0 ≤ 50 mm), transverse wrapping increases axial load capacity by 2.7–2.9%, whereas under high eccentricity (e0 = 220 mm), the hybrid C2 scheme enhances ultimate load-carrying capacity by 9.4% and bending moment resistance up to 260.0 kN·m, providing more than twice the gain of transverse wrapping alone.

Vol. 1(2)
Jizzakh Polytechnic Institute (UZ)
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon