Design and Load Characterization of a 16-Stage SiC Marx Generator for Nanosecond Pulsed Electric Field Experiments

Nanosecond pulsed electric field experiments require characterization of the delivered waveform under the intended load conditions. This study presents a 16-stage diode-isolated silicon carbide Marx generator and compares the load-terminal voltage waveforms for a resistive reference, a cell suspension, and ex vivo porcine fat and muscle. Each stage uses a 1 μF storage capacitor, two parallel MOSFETs, and transformer-isolated gate drive. At a 1 kV charging-supply setting and a 10 Hz repetition rate, the displayed 200 and 300 ns command traces show differences in pulse establishment and recovery. The suspension shows slower establishment and damped ringing. For the archived ex vivo porcine tissue traces at 200 and 300 ns programmed command widths, the plot-derived 90–10% voltage-recovery intervals are approximately 150 ns for fat at both widths and 50 and 40 ns for muscle, respectively. An ideal discharge model predicts 9.15% droop over 300 ns for 1 μF per stage and an assumed 50 Ω load. The comparison supports reporting the terminal-voltage history and fixture configuration alongside programmed settings.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-11-26
DOI
https://doi.org/10.3390/electronics15235535
Primary Topic
Pulsed Power Technology Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Design and Load Characterization of a 16-Stage SiC Marx Generator for Nanosecond Pulsed Electric Field Experiments

Wen Zhou Sun, Xiaodong Chen, Liyang Yu, Wen Dang et al.
Electronics
Pulsed Power Technology Applications
article

Design and Load Characterization of a 16-Stage SiC Marx Generator for Nanosecond Pulsed Electric Field Experiments

Wen Zhou Sun, Xiaodong Chen, Liyang Yu, Wen Dang, Xin Rao, Zheyi Xu, Junchen Zhou
article en

Abstract

Nanosecond pulsed electric field experiments require characterization of the delivered waveform under the intended load conditions. This study presents a 16-stage diode-isolated silicon carbide Marx generator and compares the load-terminal voltage waveforms for a resistive reference, a cell suspension, and ex vivo porcine fat and muscle. Each stage uses a 1 μF storage capacitor, two parallel MOSFETs, and transformer-isolated gate drive. At a 1 kV charging-supply setting and a 10 Hz repetition rate, the displayed 200 and 300 ns command traces show differences in pulse establishment and recovery. The suspension shows slower establishment and damped ringing. For the archived ex vivo porcine tissue traces at 200 and 300 ns programmed command widths, the plot-derived 90–10% voltage-recovery intervals are approximately 150 ns for fat at both widths and 50 and 40 ns for muscle, respectively. An ideal discharge model predicts 9.15% droop over 300 ns for 1 μF per stage and an assumed 50 Ω load. The comparison supports reporting the terminal-voltage history and fixture configuration alongside programmed settings.

ElectronicsVol. 15(23)
Queen Mary University of London (GB), Hangzhou Dianzi University (CN)
Pulsed Power Technology Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon