Loss of plasminogen activator inhibitor-1 activity during liquid plasma storage is associated with increased fibrinolysis in response to tissue plasminogen activator

BACKGROUND: In trauma, hyperfibrinolysis influences the need for massive transfusion and mortality. Tissue plasminogen activator (tPA) sensitivity increases during whole blood storage despite rising plasminogen activator inhibitor-1 (PAI-1) activity. Liquid plasma demonstrates preserved fibrinogen function in storage, but fibrinolytic regulation in stored liquid plasma remains undescribed. METHODS: Liquid plasma tails (n = 28) were obtained and stored at 4 °C. Thromboelastography was challenged with 75 ng/mL exogenous tPA at three storage time points (day 1–3, 7–10, and 28) to assess resistance to fibrinolysis. PAI-1 activity was measured through a modified enzyme-linked immunosorbent assay (ELISA) that captures only active PAI-1 utilizing immobilized active urokinase. Statistical analysis included two-way analysis of variance (ANOVA) and Spearman correlation. Significance was set at p <0.05. RESULTS: Aging liquid plasma units demonstrated a significant, progressive increase in fibrinolysis (LY30) in response to tPA over time (p = 0.008). Alpha angle gradually increased, and maximum amplitude remained stable with storage. PAI-1 activity decreased with storage (p < 0.001) and inversely correlated with tPA-thromboelastography LY30 (Spearman r = -0.40, p = 0.04). CONCLUSIONS: Stored liquid plasma demonstrates declining PAI-1 activity, increased tPA-mediated fibrinolysis, and preserved clot strength, highlighting differences in fibrinolytic regulation compared with previously reported findings in stored whole blood. Further investigation into fibrinolytic regulation for the spectrum of blood products during storage and the implications for trauma resuscitation is warranted. LEVEL OF EVIDENCE: Basic Science.

Authors

Publication Details

Journal
The Journal of Trauma: Injury, Infection, and Critical Care
Published
2026-11-26
DOI
https://doi.org/10.1097/ta.0000000000005243
Primary Topic
Trauma, Hemostasis, Coagulopathy, Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Loss of plasminogen activator inhibitor-1 activity during liquid plasma storage is associated with increased fibrinolysis in response to tissue plasminogen activator

Ashley A. Clegg, Christopher D. Barrett, Peter K. Moore, Hunter B. Moore et al.
The Journal of Trauma: Injury, Infection, and Critical Care
Trauma, Hemostasis, Coagulopathy, Resuscitation
article

Loss of plasminogen activator inhibitor-1 activity during liquid plasma storage is associated with increased fibrinolysis in response to tissue plasminogen activator

Ashley A. Clegg, Christopher D. Barrett, Peter K. Moore, Hunter B. Moore, Collin M. White, Reynold Henry, Scott A. Koepsell, Aleh Bobr, Flobater I. Gawargi, Elizabeth R. Maginot, Nicolle K. Barmettler, Shelly Williams, Ernest E. Moore, Trace B Moody, Natasha Goodman, Mohamed Hamed
article en

Abstract

BACKGROUND: In trauma, hyperfibrinolysis influences the need for massive transfusion and mortality. Tissue plasminogen activator (tPA) sensitivity increases during whole blood storage despite rising plasminogen activator inhibitor-1 (PAI-1) activity. Liquid plasma demonstrates preserved fibrinogen function in storage, but fibrinolytic regulation in stored liquid plasma remains undescribed. METHODS: Liquid plasma tails (n = 28) were obtained and stored at 4 °C. Thromboelastography was challenged with 75 ng/mL exogenous tPA at three storage time points (day 1–3, 7–10, and 28) to assess resistance to fibrinolysis. PAI-1 activity was measured through a modified enzyme-linked immunosorbent assay (ELISA) that captures only active PAI-1 utilizing immobilized active urokinase. Statistical analysis included two-way analysis of variance (ANOVA) and Spearman correlation. Significance was set at p <0.05. RESULTS: Aging liquid plasma units demonstrated a significant, progressive increase in fibrinolysis (LY30) in response to tPA over time (p = 0.008). Alpha angle gradually increased, and maximum amplitude remained stable with storage. PAI-1 activity decreased with storage (p < 0.001) and inversely correlated with tPA-thromboelastography LY30 (Spearman r = -0.40, p = 0.04). CONCLUSIONS: Stored liquid plasma demonstrates declining PAI-1 activity, increased tPA-mediated fibrinolysis, and preserved clot strength, highlighting differences in fibrinolytic regulation compared with previously reported findings in stored whole blood. Further investigation into fibrinolytic regulation for the spectrum of blood products during storage and the implications for trauma resuscitation is warranted. LEVEL OF EVIDENCE: Basic Science.

The Journal of Trauma: Injury, Infection, and Critical Care
Trauma, Hemostasis, Coagulopathy, Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon