Diagnostic thresholds, cut-offs, and scoring controversies: a modelling study of sampling and diagnostic performance

Background. Three controversies occupy diagnostic pathology: where a diagnostic threshold belongs, where a cut-off belongs inside a measurement range, and which scoring system measures treatment effect. Each concerns a readout several layers from the process that generates disease. We read that distance as layer distance, tested whether three models reproduce threshold loss, cut-off loss and scoring window, and used an energy checkpoint to set a common ceiling. Methods. We defined six layers (energy, driver, precursor, lesion, product, molecular readout) and counted layer distance d as layers between sampling channel and driver. Three PubMed blocks returned 5,640 records; a PRISMA workflow selected 75 studies. Model 1 fitted R(d) = exp(−λd) to seven paired tissue–plasma comparisons. Model 2 decomposed kappa at a binary cut-off into an ordinal baseline minus binarisation loss and specimen-size loss. Model 3 fitted R(t) = R₀·exp(− t/τ) to eight discontinuation and long-term series. Substituting the energy checkpoint E(a) of four cancers gave the age equivalent of one layer. Results. One layer retained 0.302–0.811 of upstream sensitivity (median 0.470), with a median decay coefficient of 0.755 per layer and a half-distance of 0.92 layers. A marker panel gained 0.08–0.45 of a layer. Binarisation cost 0.187–0.384 of kappa; specimen size cost a further 0.092. Recovery constants spanned 0.07–16.31 years (238-fold); a fixed one-year window read 0–94% of the effect. Late-phase energy decay was 0.188–0.208 per year; one layer equalled 4.01 years, and the three time scales of energy half-life, layer distance and treatment recovery (3.68, 4.01 and 4.55 years) all fell between 3.7 and 4.6 years. Conclusions. The three controversies share one quantity: the distance between measuring channel and process. Layer distance sets the threshold, binarisation sets the cut-off, and the recovery constant sets the scoring window. Diagnostic improvement has a ceiling at the energy end; earlier detection requires moving the sampling channel upstream, or sampling before E(a) has decayed. E(a) also decides whether a precancerous sequence exists: children hold E near its full value and carry no long precursor, whereas adults hold decayed E and pass through a precancerous stage.

Authors

Publication Details

Journal
Research Square
Published
2026-11-27
DOI
https://doi.org/10.21203/rs.3.rs-11704622/v1
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Diagnostic thresholds, cut-offs, and scoring controversies: a modelling study of sampling and diagnostic performance

Yuting Ma, wei qiaoxuan, guijuan zhu
Research Square
Clinical Laboratory Practices and Quality Control
preprint

Diagnostic thresholds, cut-offs, and scoring controversies: a modelling study of sampling and diagnostic performance

Yuting Ma, wei qiaoxuan, guijuan zhu
preprint en

Abstract

Background. Three controversies occupy diagnostic pathology: where a diagnostic threshold belongs, where a cut-off belongs inside a measurement range, and which scoring system measures treatment effect. Each concerns a readout several layers from the process that generates disease. We read that distance as layer distance, tested whether three models reproduce threshold loss, cut-off loss and scoring window, and used an energy checkpoint to set a common ceiling. Methods. We defined six layers (energy, driver, precursor, lesion, product, molecular readout) and counted layer distance d as layers between sampling channel and driver. Three PubMed blocks returned 5,640 records; a PRISMA workflow selected 75 studies. Model 1 fitted R(d) = exp(−λd) to seven paired tissue–plasma comparisons. Model 2 decomposed kappa at a binary cut-off into an ordinal baseline minus binarisation loss and specimen-size loss. Model 3 fitted R(t) = R₀·exp(− t/τ) to eight discontinuation and long-term series. Substituting the energy checkpoint E(a) of four cancers gave the age equivalent of one layer. Results. One layer retained 0.302–0.811 of upstream sensitivity (median 0.470), with a median decay coefficient of 0.755 per layer and a half-distance of 0.92 layers. A marker panel gained 0.08–0.45 of a layer. Binarisation cost 0.187–0.384 of kappa; specimen size cost a further 0.092. Recovery constants spanned 0.07–16.31 years (238-fold); a fixed one-year window read 0–94% of the effect. Late-phase energy decay was 0.188–0.208 per year; one layer equalled 4.01 years, and the three time scales of energy half-life, layer distance and treatment recovery (3.68, 4.01 and 4.55 years) all fell between 3.7 and 4.6 years. Conclusions. The three controversies share one quantity: the distance between measuring channel and process. Layer distance sets the threshold, binarisation sets the cut-off, and the recovery constant sets the scoring window. Diagnostic improvement has a ceiling at the energy end; earlier detection requires moving the sampling channel upstream, or sampling before E(a) has decayed. E(a) also decides whether a precancerous sequence exists: children hold E near its full value and carry no long precursor, whereas adults hold decayed E and pass through a precancerous stage.

Research Square
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon