An early diagnosis method for micro-short circuits in lithium-ion batteries based on standardised residuals and CUSUM sequential analysis
Early micro-short-circuit faults in lithium-ion battery packs are difficult to detect because their voltage deviations are weak, strongly coupled with pack-level variations, and easily obscured by operating-condition changes, measurement noise and coexisting cell anomalies. To address these challenges, this study proposes a hierarchical anomaly detection and localisation framework integrating robust deviation extraction, adaptive Kalman filtering (AKF), multi-feature fusion, cumulative sum (CUSUM) detection, adaptive DBSCAN clustering, and recursive risk modelling. A seven-dimensional feature representation is constructed to jointly characterise static deviation, dynamic variation, standardised innovation, temporal accumulation, neighbouring-cell inconsistency and population ranking. CUSUM enhances persistent weak deviations, adaptive DBSCAN identifies population-level outliers, and recursive risk modelling suppresses transient fluctuations to achieve stable warning and localisation. The proposed framework was validated using both controlled micro-short-circuit experiments and real-vehicle operation data. On the real-vehicle dataset, Cell 195 was correctly identified with a final rank of 1, a mean rank of 3.71, and an anti-misleading rate (AMR) of 0.770. Compared with Isolation Forest, Local Outlier Factor, and One-Class SVM, the proposed method achieved the lowest mean rank without requiring offline training of the anomaly-detection model; only the decision thresholds can be calibrated offline for deployment. Ablation experiments demonstrated complementary contributions of individual modules: removing AKF reduced AMR from 0.770 to 0.628, removing DBSCAN delayed the first alarm from sample 12 to 57, and removing risk recursion increased the mean rank from 3.71 to 8.45. Parameter sensitivity analysis further showed stable final localisation across 15 parameter configurations. For a 216-cell pack, the processing time was approximately 2.856 ms per sampling step, while the final localisation rate remained 100% under measurement noise and missing-data disturbances. These results demonstrate a balanced combination of weak-fault sensitivity, interference resistance, temporal stability and real-time feasibility for online battery-management applications.
Authors
- Kan Zhao
- Lihua Ye (ORCID: https://orcid.org/0009-0008-7802-5669)
- A. SHI (ORCID: https://orcid.org/0009-0009-7663-6527)
- Zi-xuan He
- Jing-xin Li
- Qing-long Zhao
Institutions
- Jiangsu University (CN)
Publication Details
- Journal
- Proceedings of the Institution of Mechanical Engineers Part D Journal of Automobile Engineering
- Published
- 2026-11-25
- DOI
- https://doi.org/10.1177/09544070261504692
- Primary Topic
- Battery Modeling and Management
- Type
- article
- Field-Weighted Citation Impact
- 0.00