Identification and validation of composite performance boundaries for an electro-hydrostatic actuator under multi-source degradation and task loads

Assessing an electro-hydrostatic actuator (EHA) before repeated task execution requires identifying acceptable degradation states under the intended load. This study develops a framework for identifying composite performance boundaries under a prescribed reciprocating actuation task, accounting for pump leakage, reduced controller proportional gain, and external load. AMESim simulations and Gaussian process regression (GPR) relate degradation parameters and task load to maximum displacement-response deviation, steady-state displacement-response deviation, and settling time. A composite performance margin combines the three requirements. Zero-level-set extraction and connected-component selection identify the main acceptable degradation domain connected to the healthy state. The analysis determines governing constraints and their transitions and evaluates load and threshold effects. Independent simulations, AMESim boundary cross-sections, and bench tests validate the performance maps and boundary predictions. Maximum displacement-response deviation and settling time govern different segments of the main composite boundary, whereas steady-state displacement-response deviation does not govern any segment of that boundary. Increasing load from 1000 to 3000 N reduces domain area by approximately 17.5%. Tightening the settling-time threshold by 5% reduces area by approximately 26–29%. Across 15 boundary cross-sections, the boundary-location root mean square error is 0.004527 in normalized degradation coordinates. The predicted task-state classifications agree with the bench-test classifications for all seven cases, although discrepancies remain in the composite performance margins. The framework identifies the principal performance constraints and acceptable degradation range under the specified task conditions, supporting system-level degradation performance assessment.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-26
DOI
https://doi.org/10.21203/rs.3.rs-11794702/v1
Primary Topic
Hydraulic and Pneumatic Systems
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Identification and validation of composite performance boundaries for an electro-hydrostatic actuator under multi-source degradation and task loads

Huanguo Chen, Haohan Tao, Jianwei Wu, Naihao Liu et al.
Research Square
Hydraulic and Pneumatic Systems
preprint

Identification and validation of composite performance boundaries for an electro-hydrostatic actuator under multi-source degradation and task loads

Huanguo Chen, Haohan Tao, Jianwei Wu, Naihao Liu, hui liu, shimin feng, tian lan, peng zhang
preprint en

Abstract

Assessing an electro-hydrostatic actuator (EHA) before repeated task execution requires identifying acceptable degradation states under the intended load. This study develops a framework for identifying composite performance boundaries under a prescribed reciprocating actuation task, accounting for pump leakage, reduced controller proportional gain, and external load. AMESim simulations and Gaussian process regression (GPR) relate degradation parameters and task load to maximum displacement-response deviation, steady-state displacement-response deviation, and settling time. A composite performance margin combines the three requirements. Zero-level-set extraction and connected-component selection identify the main acceptable degradation domain connected to the healthy state. The analysis determines governing constraints and their transitions and evaluates load and threshold effects. Independent simulations, AMESim boundary cross-sections, and bench tests validate the performance maps and boundary predictions. Maximum displacement-response deviation and settling time govern different segments of the main composite boundary, whereas steady-state displacement-response deviation does not govern any segment of that boundary. Increasing load from 1000 to 3000 N reduces domain area by approximately 17.5%. Tightening the settling-time threshold by 5% reduces area by approximately 26–29%. Across 15 boundary cross-sections, the boundary-location root mean square error is 0.004527 in normalized degradation coordinates. The predicted task-state classifications agree with the bench-test classifications for all seven cases, although discrepancies remain in the composite performance margins. The framework identifies the principal performance constraints and acceptable degradation range under the specified task conditions, supporting system-level degradation performance assessment.

Research Square
Zhejiang Sci-Tech University (CN)
Hydraulic and Pneumatic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon