Accelerated Multi-Shot Diffusion-Weighted MRI of the Head and Neck Using Deep Learning Reconstruction

Purpose High-resolution imaging of the head and neck is crucial, with diffusion-weighted imaging (DWI) providing high diagnostic value. Patient-related factors such as comorbidities and difficulty remaining still make shorter scan times desirable while preserving image quality. This study aims to evaluate the feasibility of deep learning-reconstructed DWI for routine head and neck MRI. Methods In this study, two readout-segmented echo-planar imaging (rs-EPI) DWI acquisitions were performed on a 1.5 T scanner in 55 patients undergoing indicated MRI: a sequence reconstructed conventionally (c-DWI) and a prototype deep learning-reconstructed rs-EPI (DL-DWI). Scan time of DL-DWI was decreased by 40%. The datasets were evaluated by three radiologists using a 4-point Likert scale for image quality, diagnostic confidence, pathology assessment, artifacts and anatomical regions. Objective quantitative image analysis evaluated signal intensity (SI), signal-to-noise ratio (SNR), and the ratio of voxels above diagnostic threshold compared to the total number of voxels (NumVox). Fleiss’s kappa (ϰ) determined inter-rater agreement. Results DL-DWI was superior, particularly in image quality, diagnostic confidence, pathology assessment, and evaluation of anatomical regions (p < 0.001). 63.6% of DL-DWI images showed excellent image quality, compared to 7.3% for c‑DWI (p < 0.001). Artifacts were the only parameter for which DL-DWI was not superior. However, readers were confident in classifying artifacts, and DL-DWI showed no false-negative or false-positive findings. Inter-rater agreement was nearly perfect for both, with higher values for DL-DWI. DL-DWI showed significantly higher NumVox and SNR (p < 0.001). Conclusion DL-DWI markedly improves image quality and acquisition efficiency, reducing scan time by almost 50%.

Authors

Institutions

Publication Details

Journal
Clinical Neuroradiology
Published
2026-11-26
DOI
https://doi.org/10.1007/s00062-026-01746-1
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Accelerated Multi-Shot Diffusion-Weighted MRI of the Head and Neck Using Deep Learning Reconstruction

Omar Isam Darwish, Sebastian Altmann, Maximilian Krüger, Andrea Kronfeld et al.
Clinical Neuroradiology
Advanced MRI Techniques and Applications
article

Accelerated Multi-Shot Diffusion-Weighted MRI of the Head and Neck Using Deep Learning Reconstruction

Omar Isam Darwish, Sebastian Altmann, Maximilian Krüger, Andrea Kronfeld, Roman H. Paul, Ahmed E. Othman, Mohammed khalaf, Marc Alexander Brockmann, Vanessa I Schöffling, Leon Heiden, Liu Wei, Sophie Runkel, Haidara Al Mansour
article en

Abstract

Purpose High-resolution imaging of the head and neck is crucial, with diffusion-weighted imaging (DWI) providing high diagnostic value. Patient-related factors such as comorbidities and difficulty remaining still make shorter scan times desirable while preserving image quality. This study aims to evaluate the feasibility of deep learning-reconstructed DWI for routine head and neck MRI. Methods In this study, two readout-segmented echo-planar imaging (rs-EPI) DWI acquisitions were performed on a 1.5 T scanner in 55 patients undergoing indicated MRI: a sequence reconstructed conventionally (c-DWI) and a prototype deep learning-reconstructed rs-EPI (DL-DWI). Scan time of DL-DWI was decreased by 40%. The datasets were evaluated by three radiologists using a 4-point Likert scale for image quality, diagnostic confidence, pathology assessment, artifacts and anatomical regions. Objective quantitative image analysis evaluated signal intensity (SI), signal-to-noise ratio (SNR), and the ratio of voxels above diagnostic threshold compared to the total number of voxels (NumVox). Fleiss’s kappa (ϰ) determined inter-rater agreement. Results DL-DWI was superior, particularly in image quality, diagnostic confidence, pathology assessment, and evaluation of anatomical regions (p < 0.001). 63.6% of DL-DWI images showed excellent image quality, compared to 7.3% for c‑DWI (p < 0.001). Artifacts were the only parameter for which DL-DWI was not superior. However, readers were confident in classifying artifacts, and DL-DWI showed no false-negative or false-positive findings. Inter-rater agreement was nearly perfect for both, with higher values for DL-DWI. DL-DWI showed significantly higher NumVox and SNR (p < 0.001). Conclusion DL-DWI markedly improves image quality and acquisition efficiency, reducing scan time by almost 50%.

Clinical Neuroradiology
Johannes Gutenberg University Mainz (DE), University Medical Center of the Johannes Gutenberg University Mainz (DE), Siemens Healthineers (Germany) (DE)
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon