Impact of Cardiac CT–Defined True Septal Right Ventricular Lead Position on Electrical and Structural Remodeling After Cardiac Resynchronization Therapy With Defibrillator Implantation
INTRODUCTION: The impact of true right ventricular (RV) septal lead positioning on response to cardiac resynchronization therapy (CRT) remains controversial. We investigated the association between cardiac computed tomography (CT)-defined RV defibrillator lead position and CRT response. METHODS: This retrospective study included 105 patients who underwent CRT-defibrillator (CRT-D) implantation and post-implantation cardiac CT to assess RV lead position. All patients had documented biventricular pacing ≥ 90% at 6 months. Based on CT findings, patients were classified into a true septal RV lead group (n = 56) and a non-septal group (n = 49). Changes in QRS duration and echocardiographic parameters at 6 months and long-term clinical outcomes were compared between the groups. CRT response was defined as a ≥ 15% reduction in left ventricular end-systolic volume (LVESV) at 6 months. RESULTS: Post-implantation QRS duration was significantly shorter in the septal group than in the non-septal group (136.2 ± 15.8 vs. 157.4 ± 21.8 ms, p < 0.001). At 6 months, the septal group showed greater improvements in left ventricular ejection fraction (Δ8.4 ± 9.7% vs. 3.8 ± 8.5%, p = 0.011) and LVESV (Δ-31.8 ± 39.2 vs. -11.9 ± 39.1 mL, p = 0.013), with a higher CRT response rate (73.2% vs. 42.9%, p = 0.003). Multivariable analysis demonstrated that true septal RV lead positioning was independently associated with CRT response (odds ratio, 3.33; 95% confidence interval, 1.13-9.78; p = 0.029). No significant between-group differences were observed in mortality or heart failure hospitalization. CONCLUSIONS: Cardiac CT-defined true septal RV lead positioning was associated with greater electrical resynchronization and enhanced LV reverse remodeling after CRT-D implantation. Anatomical RV lead position may represent an important modifiable determinant of CRT response.
Authors
- Yukiomi Tsuji (ORCID: https://orcid.org/0000-0003-4836-3057)
- Yasuya Inden (ORCID: https://orcid.org/0000-0001-5732-5672)
- Hideki Ishii (ORCID: https://orcid.org/0000-0003-4348-0123)
- Toyoaki Murohara (ORCID: https://orcid.org/0000-0003-2723-6243)
- Kentaro Adachi
- Tsubasa Teraoka
- Taishi Fukushima (ORCID: https://orcid.org/0000-0002-0304-7096)
- Shotaro Hiramatsu (ORCID: https://orcid.org/0009-0000-8944-9936)
- Takehiro Hiramatsu
- Ryusuke Ota
- Satoshi Yanagisawa (ORCID: https://orcid.org/0000-0002-0658-5498)
- Masafumi Shimojo (ORCID: https://orcid.org/0009-0009-8523-7771)
- Taiki Kitahara (ORCID: https://orcid.org/0009-0001-0124-3413)
- Yuki Tanaka
Institutions
- Nagoya University (JP)
Publication Details
- Journal
- Journal of Cardiovascular Electrophysiology
- Published
- 2026-11-25
- DOI
- https://doi.org/10.1111/jce.70566
- Primary Topic
- Cardiac pacing and defibrillation studies
- Type
- article
- Field-Weighted Citation Impact
- 0.00