Impact of Cardiac CT–Defined True Septal Right Ventricular Lead Position on Electrical and Structural Remodeling After Cardiac Resynchronization Therapy With Defibrillator Implantation

INTRODUCTION: The impact of true right ventricular (RV) septal lead positioning on response to cardiac resynchronization therapy (CRT) remains controversial. We investigated the association between cardiac computed tomography (CT)-defined RV defibrillator lead position and CRT response. METHODS: This retrospective study included 105 patients who underwent CRT-defibrillator (CRT-D) implantation and post-implantation cardiac CT to assess RV lead position. All patients had documented biventricular pacing ≥ 90% at 6 months. Based on CT findings, patients were classified into a true septal RV lead group (n = 56) and a non-septal group (n = 49). Changes in QRS duration and echocardiographic parameters at 6 months and long-term clinical outcomes were compared between the groups. CRT response was defined as a ≥ 15% reduction in left ventricular end-systolic volume (LVESV) at 6 months. RESULTS: Post-implantation QRS duration was significantly shorter in the septal group than in the non-septal group (136.2 ± 15.8 vs. 157.4 ± 21.8 ms, p < 0.001). At 6 months, the septal group showed greater improvements in left ventricular ejection fraction (Δ8.4 ± 9.7% vs. 3.8 ± 8.5%, p = 0.011) and LVESV (Δ-31.8 ± 39.2 vs. -11.9 ± 39.1 mL, p = 0.013), with a higher CRT response rate (73.2% vs. 42.9%, p = 0.003). Multivariable analysis demonstrated that true septal RV lead positioning was independently associated with CRT response (odds ratio, 3.33; 95% confidence interval, 1.13-9.78; p = 0.029). No significant between-group differences were observed in mortality or heart failure hospitalization. CONCLUSIONS: Cardiac CT-defined true septal RV lead positioning was associated with greater electrical resynchronization and enhanced LV reverse remodeling after CRT-D implantation. Anatomical RV lead position may represent an important modifiable determinant of CRT response.

Authors

Institutions

Publication Details

Journal
Journal of Cardiovascular Electrophysiology
Published
2026-11-25
DOI
https://doi.org/10.1111/jce.70566
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Impact of Cardiac CT–Defined True Septal Right Ventricular Lead Position on Electrical and Structural Remodeling After Cardiac Resynchronization Therapy With Defibrillator Implantation

Yukiomi Tsuji, Yasuya Inden, Hideki Ishii, Toyoaki Murohara et al.
Journal of Cardiovascular Electrophysiology
Cardiac pacing and defibrillation studies
article

Impact of Cardiac CT–Defined True Septal Right Ventricular Lead Position on Electrical and Structural Remodeling After Cardiac Resynchronization Therapy With Defibrillator Implantation

Yukiomi Tsuji, Yasuya Inden, Hideki Ishii, Toyoaki Murohara, Kentaro Adachi, Tsubasa Teraoka, Taishi Fukushima, Shotaro Hiramatsu, Takehiro Hiramatsu, Ryusuke Ota, Satoshi Yanagisawa, Masafumi Shimojo, Taiki Kitahara, Yuki Tanaka
article en

Abstract

INTRODUCTION: The impact of true right ventricular (RV) septal lead positioning on response to cardiac resynchronization therapy (CRT) remains controversial. We investigated the association between cardiac computed tomography (CT)-defined RV defibrillator lead position and CRT response. METHODS: This retrospective study included 105 patients who underwent CRT-defibrillator (CRT-D) implantation and post-implantation cardiac CT to assess RV lead position. All patients had documented biventricular pacing ≥ 90% at 6 months. Based on CT findings, patients were classified into a true septal RV lead group (n = 56) and a non-septal group (n = 49). Changes in QRS duration and echocardiographic parameters at 6 months and long-term clinical outcomes were compared between the groups. CRT response was defined as a ≥ 15% reduction in left ventricular end-systolic volume (LVESV) at 6 months. RESULTS: Post-implantation QRS duration was significantly shorter in the septal group than in the non-septal group (136.2 ± 15.8 vs. 157.4 ± 21.8 ms, p < 0.001). At 6 months, the septal group showed greater improvements in left ventricular ejection fraction (Δ8.4 ± 9.7% vs. 3.8 ± 8.5%, p = 0.011) and LVESV (Δ-31.8 ± 39.2 vs. -11.9 ± 39.1 mL, p = 0.013), with a higher CRT response rate (73.2% vs. 42.9%, p = 0.003). Multivariable analysis demonstrated that true septal RV lead positioning was independently associated with CRT response (odds ratio, 3.33; 95% confidence interval, 1.13-9.78; p = 0.029). No significant between-group differences were observed in mortality or heart failure hospitalization. CONCLUSIONS: Cardiac CT-defined true septal RV lead positioning was associated with greater electrical resynchronization and enhanced LV reverse remodeling after CRT-D implantation. Anatomical RV lead position may represent an important modifiable determinant of CRT response.

Journal of Cardiovascular Electrophysiology
Nagoya University (JP)
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon