Investigating short-term variations of per- and polyfluoroalkyl substances (PFAS) in four Australian wastewater treatment plants

Per- and polyfluoroalkyl substances (PFAS) monitoring at wastewater treatment plants (WWTPs) often relies on isolated samples, obscuring the relative importance of short-term fluctuations and persistent catchment sources. 24-h composite influent and effluent samples were collected over seven consecutive days at four Australian WWTPs during autumn and spring 2023. Median concentrations of the sum of 47 target PFAS (Σ 47 PFAS) ranged from 11 to 71 ng L −1 at W1–W3, where perfluoroalkyl carboxylic acids (PFCA) predominated, but reached 415–507 ng L −1 at W4. At W4, perfluoroalkane sulfonic acids (PFSA) accounted for 83–85% of Σ 47 PFAS, dominated by PFHxS and PFOS (73–76%), suggesting a distinct fingerprint potentially linked to groundwater contaminated by electrochemically fluorinated aqueous film-forming foams. Influent–effluent patterns varied among plants and seasons, where Σ 47 PFAS concentrations in effluent were generally higher, except at W1 in autumn and W4 in spring, and short-chain PFCAs were enriched in effluent. Despite isolated site- and stream-specific differences, daily Σ 47 PFAS concentrations were broadly stable, while plant-to-plant variation remained noticeable. Estimated annual effluent discharge from individual WWTPs ranged from 0.01 kg year −1 at W3 to 13 kg year −1 at W1. Although W4 had the highest PFAS concentrations, its comparatively low effluent flow limited its total annual discharge to approximately 2 kg year −1 . When normalised to the population served, however, W4 had the highest per capita effluent load (137 μg d −1 person −1 ). Using W3 as a domestic reference (5 μg d −1 person −1 ) suggests that Australian households contribute approximately 34 kg of PFAS to wastewater each year. These findings address a globally relevant monitoring challenge by showing that catchment sources and hydraulic scale can outweigh short-term variability. Population-normalised domestic baselines offer a transferable framework for detecting non-domestic hotspots, designing representative monitoring and prioritising upstream PFAS controls worldwide.

Authors

Institutions

Publication Details

Journal
Chemosphere
Published
2026-11-26
DOI
https://doi.org/10.1016/j.chemosphere.2026.145154
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Investigating short-term variations of per- and polyfluoroalkyl substances (PFAS) in four Australian wastewater treatment plants

Zahra Sobhani, Bradley O. Clarke, Jordan M Partington, Mulugeta Legesse Akele et al.
Chemosphere
Per- and polyfluoroalkyl substances research
article

Investigating short-term variations of per- and polyfluoroalkyl substances (PFAS) in four Australian wastewater treatment plants

Zahra Sobhani, Bradley O. Clarke, Jordan M Partington, Mulugeta Legesse Akele, Stefano Freguia, Jaye Marchiandi, Wejdan Saleh Alghamdi, Madara Weerasooriyagedra
article en

Abstract

Per- and polyfluoroalkyl substances (PFAS) monitoring at wastewater treatment plants (WWTPs) often relies on isolated samples, obscuring the relative importance of short-term fluctuations and persistent catchment sources. 24-h composite influent and effluent samples were collected over seven consecutive days at four Australian WWTPs during autumn and spring 2023. Median concentrations of the sum of 47 target PFAS (Σ 47 PFAS) ranged from 11 to 71 ng L −1 at W1–W3, where perfluoroalkyl carboxylic acids (PFCA) predominated, but reached 415–507 ng L −1 at W4. At W4, perfluoroalkane sulfonic acids (PFSA) accounted for 83–85% of Σ 47 PFAS, dominated by PFHxS and PFOS (73–76%), suggesting a distinct fingerprint potentially linked to groundwater contaminated by electrochemically fluorinated aqueous film-forming foams. Influent–effluent patterns varied among plants and seasons, where Σ 47 PFAS concentrations in effluent were generally higher, except at W1 in autumn and W4 in spring, and short-chain PFCAs were enriched in effluent. Despite isolated site- and stream-specific differences, daily Σ 47 PFAS concentrations were broadly stable, while plant-to-plant variation remained noticeable. Estimated annual effluent discharge from individual WWTPs ranged from 0.01 kg year −1 at W3 to 13 kg year −1 at W1. Although W4 had the highest PFAS concentrations, its comparatively low effluent flow limited its total annual discharge to approximately 2 kg year −1 . When normalised to the population served, however, W4 had the highest per capita effluent load (137 μg d −1 person −1 ). Using W3 as a domestic reference (5 μg d −1 person −1 ) suggests that Australian households contribute approximately 34 kg of PFAS to wastewater each year. These findings address a globally relevant monitoring challenge by showing that catchment sources and hydraulic scale can outweigh short-term variability. Population-normalised domestic baselines offer a transferable framework for detecting non-domestic hotspots, designing representative monitoring and prioritising upstream PFAS controls worldwide.

ChemosphereVol. 416
The University of Melbourne (AU), University of Bisha (SA), University of Gondar (ET)
Per- and polyfluoroalkyl substances research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.