Artificial Intelligence‐Assisted Electrochemical Detection of Tryptophan on Modified Glassy Carbon Electrode: A Comparative Machine Learning Approach

The rapid and accurate determination of low concentration of tryptophan is critical for the surveillance of human health and quality control of food. An electrochemical probe of vanadium oxide and reduced graphene oxide deposited on a glassy carbon electrode (GCE) for accurate measurement of TRP. Moreover, outcome of two key parameters, namely peak voltage and current on sensor performance for TRP detection, was systematically studied. The experimental analysis yielded two input variables: peak potential (V) and peak current (µA) which yielded a 73 data points over a range of concentration of TRP between 1 and 200 µM. Seven machine learning (ML) models were used to make TRP concentration predictions using the collected data on a modified GCE. After cross‐validation on the seven tree‐based ML algorithms, the best model was selected: Bagging, Decision Tree, AdaBoost, Gradient Boosting, Hist Gradient Boosting, and Random Forest. The R 2, root mean square error (RMSE), and mean absolute error (MAE) were used to evaluate the model effectiveness. Based on overall performance and metric calculations, it was concluded that Extra Trees (ET) is the optimal structure with an R 2 value of 0.9982, RMSE of 2.75 µM, and MAE of 1.93 µM. The findings are highly consistent with measured and calculated TRP concentrations. An additional calibration plot was also built with square wave voltammetry to obtain the accurate concentration of TRP at 20–200 µM. The results revealed that developed modified GCE sensor with the ET ML model can be used for rapid and accurate quantification of tryptophan in food samples, which may provide the reliable platform for clinical amino acid analysis.

Authors

Institutions

Publication Details

Journal
Electroanalysis
Published
2026-11-25
DOI
https://doi.org/10.1002/elan.70257
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Artificial Intelligence‐Assisted Electrochemical Detection of Tryptophan on Modified Glassy Carbon Electrode: A Comparative Machine Learning Approach

Khush Bakht, Waqas Ul Arifeen, Eman A. Alzahrani, Reda A. Haggam et al.
Electroanalysis
Electrochemical sensors and biosensors
article

Artificial Intelligence‐Assisted Electrochemical Detection of Tryptophan on Modified Glassy Carbon Electrode: A Comparative Machine Learning Approach

Khush Bakht, Waqas Ul Arifeen, Eman A. Alzahrani, Reda A. Haggam, Hala M. Abo‐Dief, Sarah Abdullah Alsalhi, Muhammad Faizan, Abhinav Kumar
article en

Abstract

The rapid and accurate determination of low concentration of tryptophan is critical for the surveillance of human health and quality control of food. An electrochemical probe of vanadium oxide and reduced graphene oxide deposited on a glassy carbon electrode (GCE) for accurate measurement of TRP. Moreover, outcome of two key parameters, namely peak voltage and current on sensor performance for TRP detection, was systematically studied. The experimental analysis yielded two input variables: peak potential (V) and peak current (µA) which yielded a 73 data points over a range of concentration of TRP between 1 and 200 µM. Seven machine learning (ML) models were used to make TRP concentration predictions using the collected data on a modified GCE. After cross‐validation on the seven tree‐based ML algorithms, the best model was selected: Bagging, Decision Tree, AdaBoost, Gradient Boosting, Hist Gradient Boosting, and Random Forest. The R 2, root mean square error (RMSE), and mean absolute error (MAE) were used to evaluate the model effectiveness. Based on overall performance and metric calculations, it was concluded that Extra Trees (ET) is the optimal structure with an R 2 value of 0.9982, RMSE of 2.75 µM, and MAE of 1.93 µM. The findings are highly consistent with measured and calculated TRP concentrations. An additional calibration plot was also built with square wave voltammetry to obtain the accurate concentration of TRP at 20–200 µM. The results revealed that developed modified GCE sensor with the ET ML model can be used for rapid and accurate quantification of tryptophan in food samples, which may provide the reliable platform for clinical amino acid analysis.

ElectroanalysisVol. 38(12)
Princess Nourah bint Abdulrahman University (SA), Gachon University (KR), Gomal University (PK), Taif University (SA), Western Caspian University (AZ), Islamic University of Madinah (SA), Yeungnam University (KR), Chitkara University (IN)
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon