Axial performance of concrete-encased cold-formed steel composite columns with optimized stiffened sections

Concrete-encased cold-formed steel (CFS) composite columns combine the advantages of steel and concrete, offering high strength, stiffness, and durability for structural applications. However, the thin-walled nature of cold-formed steel sections makes them susceptible to local buckling under axial compression, thereby limiting their structural efficiency. This study investigates the influence of flange lips and intermediate stiffeners on the axial behaviour of concrete-encased cold-formed steel composite columns through theoretical, numerical, and experimental investigations. Initially, six composite column configurations with different section arrangements were modelled and analysed using the finite element software ABAQUS. The numerical analysis evaluated the load–deflection response, load–strain behaviour, stress distribution, stiffness, and failure characteristics of the proposed columns. Based on the numerical results, three representative specimens were selected for experimental validation under axial compression, and theoretical calculations were performed to verify the predicted load-carrying capacities. The finite element predictions showed good agreement with the experimental results, confirming the reliability of the developed numerical model. The numerical results demonstrated that the incorporation of flange lips and intermediate stiffeners progressively enhanced the axial performance of the composite columns. The introduction of a 15 mm flange lip increased the ultimate load capacity by 5.56%, while the addition of one and two intermediate stiffeners increased the capacity by up to 19.84% and 30.95%, respectively, compared with the reference configuration. The optimized configuration with two intermediate stiffeners and 15 mm flange lips exhibited the highest load-carrying capacity of 825kN, together with approximately 63.4% stiffness and 19.9% lower axial deformation than the reference configuration. These improvements are attributed to increased sectional rigidity, enhanced steel–concrete interaction, and delayed local buckling of the cold-formed steel section.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-26
DOI
https://doi.org/10.1038/s41598-026-82344-6
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Axial performance of concrete-encased cold-formed steel composite columns with optimized stiffened sections

S. Suresh Babu, D. Elango, A. Leemarose, R. Surya Prakash
Scientific Reports
Structural Load-Bearing Analysis
article

Axial performance of concrete-encased cold-formed steel composite columns with optimized stiffened sections

S. Suresh Babu, D. Elango, A. Leemarose, R. Surya Prakash
article en

Abstract

Concrete-encased cold-formed steel (CFS) composite columns combine the advantages of steel and concrete, offering high strength, stiffness, and durability for structural applications. However, the thin-walled nature of cold-formed steel sections makes them susceptible to local buckling under axial compression, thereby limiting their structural efficiency. This study investigates the influence of flange lips and intermediate stiffeners on the axial behaviour of concrete-encased cold-formed steel composite columns through theoretical, numerical, and experimental investigations. Initially, six composite column configurations with different section arrangements were modelled and analysed using the finite element software ABAQUS. The numerical analysis evaluated the load–deflection response, load–strain behaviour, stress distribution, stiffness, and failure characteristics of the proposed columns. Based on the numerical results, three representative specimens were selected for experimental validation under axial compression, and theoretical calculations were performed to verify the predicted load-carrying capacities. The finite element predictions showed good agreement with the experimental results, confirming the reliability of the developed numerical model. The numerical results demonstrated that the incorporation of flange lips and intermediate stiffeners progressively enhanced the axial performance of the composite columns. The introduction of a 15 mm flange lip increased the ultimate load capacity by 5.56%, while the addition of one and two intermediate stiffeners increased the capacity by up to 19.84% and 30.95%, respectively, compared with the reference configuration. The optimized configuration with two intermediate stiffeners and 15 mm flange lips exhibited the highest load-carrying capacity of 825kN, together with approximately 63.4% stiffness and 19.9% lower axial deformation than the reference configuration. These improvements are attributed to increased sectional rigidity, enhanced steel–concrete interaction, and delayed local buckling of the cold-formed steel section.

Scientific Reports
SRM Institute of Science and Technology (IN), KCG College of Technology (IN)
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon