An Intensity-Prior-Guided Multi-Stage Artificial Intelligence Framework for Breast Lesion Detection

Breast cancer screening with mammography is essential for reducing mortality; however, achieving high sensitivity while maintaining a low false-positive rate remains challenging. The increasing workload on radiologists and the inherent difficulty of detecting subtle lesions further limit diagnostic efficiency. This study proposes an intensity-prior-guided, multi-stage artificial intelligence framework that mimics the clinical decision-making process by first identifying lesion candidate regions at the ROI level and subsequently performing ROI-guided pixel-level detection and refinement.We propose a four-stage attention-guided detection and refinement framework. In Stage 1, an intensity-informed model generates an attention map from which high-attention regions of interest (ROIs) are extracted. In Stage 2, a late-fusion decision module, integrating deep features (ConvNeXt) and radiomic features, is applied for ROI-level lesion detection with suppressed false positives while preserving sensitivity. In Stage 3, an Attention U-Net++ model performs pixel-wise segmentation to delineate lesion structures. In Stage 4, ROI bounding boxes from Stage 2 are used as spatial priors to refine segmentation outputs by suppressing predictions outside ROI regions, further reducing false positives while maintaining high sensitivity. The framework was developed using the CBIS-DDSM dataset (n = 1490), with 1190 images for training and 300 images for testing. The ROI-level detection module achieved a recall of 97.2% and a precision of 86.5%, demonstrating effective lesion candidate localization with high sensitivity. The proposed framework achieved a precision of 76.8%, a recall of 78.3%, and an F1-score of 77.4%. This study demonstrates that intensity-prior-guided spatial information can be effectively integrated into a deep learning pipeline for mammographic lesion analysis, providing a physically informed strategy for improving lesion localization and reducing false-positive segmentation.

Authors

Institutions

Publication Details

Journal
Journal of Imaging
Published
2026-11-26
DOI
https://doi.org/10.3390/jimaging12120601
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

An Intensity-Prior-Guided Multi-Stage Artificial Intelligence Framework for Breast Lesion Detection

Fang- Fang Yin, Wenbo Wan, Xiang Li, Xiaoyu Duan
Journal of Imaging
AI in cancer detection
article

An Intensity-Prior-Guided Multi-Stage Artificial Intelligence Framework for Breast Lesion Detection

Fang- Fang Yin, Wenbo Wan, Xiang Li, Xiaoyu Duan
article en

Abstract

Breast cancer screening with mammography is essential for reducing mortality; however, achieving high sensitivity while maintaining a low false-positive rate remains challenging. The increasing workload on radiologists and the inherent difficulty of detecting subtle lesions further limit diagnostic efficiency. This study proposes an intensity-prior-guided, multi-stage artificial intelligence framework that mimics the clinical decision-making process by first identifying lesion candidate regions at the ROI level and subsequently performing ROI-guided pixel-level detection and refinement.We propose a four-stage attention-guided detection and refinement framework. In Stage 1, an intensity-informed model generates an attention map from which high-attention regions of interest (ROIs) are extracted. In Stage 2, a late-fusion decision module, integrating deep features (ConvNeXt) and radiomic features, is applied for ROI-level lesion detection with suppressed false positives while preserving sensitivity. In Stage 3, an Attention U-Net++ model performs pixel-wise segmentation to delineate lesion structures. In Stage 4, ROI bounding boxes from Stage 2 are used as spatial priors to refine segmentation outputs by suppressing predictions outside ROI regions, further reducing false positives while maintaining high sensitivity. The framework was developed using the CBIS-DDSM dataset (n = 1490), with 1190 images for training and 300 images for testing. The ROI-level detection module achieved a recall of 97.2% and a precision of 86.5%, demonstrating effective lesion candidate localization with high sensitivity. The proposed framework achieved a precision of 76.8%, a recall of 78.3%, and an F1-score of 77.4%. This study demonstrates that intensity-prior-guided spatial information can be effectively integrated into a deep learning pipeline for mammographic lesion analysis, providing a physically informed strategy for improving lesion localization and reducing false-positive segmentation.

Journal of ImagingVol. 12(12)
Duke Kunshan University (CN)
AI in cancer detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
An Intensity-Prior-Guided Multi-Stage Artificial Intelligence Framework for Breast Lesion Detection — Fang- Fang Yin, Wenbo Wan, et al. · Journal of Imaging (2026) | TGRS Research Map | TGRS