A Graph-Assisted Fusion LSTM Method for Multi-Step Prediction of Reheater Wall Tube Temperature
As renewable penetration increases and deep peak-shaving operation becomes routine, reheater wall temperature is increasingly affected by load variation, combustion adjustment, steam parameter fluctuations, and multivariable coupling. These factors introduce nonlinear, delayed, and condition-dependent dynamics, which make multi-step prediction difficult. This study proposes a graph-assisted fusion long short-term memory (LSTM) model for multi-step reheater wall-temperature prediction. The model retains multivariable operating sequences as the primary temporal path, preserving the dynamic information contained in target wall-temperature history, load, air–coal parameters, and steam parameters. A fixed variable-relation graph is constructed from expert relationship constraints and mutual information estimated on the training set. Graph convolution extracts a structure-enhanced representation of the target node, which is then fused with temporal features as an auxiliary branch to generate multiple future prediction steps. Historical distributed control system data from a thermal power unit are used to construct samples under different input-window and prediction-horizon settings. Ablation experiments, multi-window comparisons, and step-wise error analysis show that graph convolutional network (GCN) and GCN-LSTM models using graph representations as the main prediction path cannot replace the original temporal path. When graph-assisted information is introduced while multivariable temporal inputs are retained, variable-coupling information is used more effectively. Under repeated-seed evaluation, the proposed model achieves mean RMSE values of 0.344, 0.784, 1.324, and 1.817 °C under the four window settings, corresponding to RMSE reductions of 20.74%, 21.68%, 12.38%, and 9.33% relative to the target-history-only LSTM model; it also outperforms CNN-LSTM in the shorter windows and remains close at the longer horizons. Step-wise RMSE analysis further indicates improved error control in the middle and later prediction steps. These findings indicate that preserving the primary temporal path while introducing graph-based relationship enhancement constrained by engineering prior knowledge provides a practical data-driven strategy for reheater wall-temperature prediction and operational risk warning.
Authors
- Weihua Qin
- Fan Geng (ORCID: https://orcid.org/0000-0001-6639-2842)
- Jiulong Wang (ORCID: https://orcid.org/0000-0003-4113-194X)
- Jia Gao (ORCID: https://orcid.org/0009-0001-9543-1051)
- He Fan
- Kai Wang
- Pengyuan Li
Institutions
- China University of Mining and Technology (CN)
- CCCC Highway Consultants (China) (CN)
- China Communications Construction Company (China) (CN)
Publication Details
- Journal
- Processes
- Published
- 2026-11-26
- DOI
- https://doi.org/10.3390/pr14233808
- Primary Topic
- Energy Load and Power Forecasting
- Type
- article
- Field-Weighted Citation Impact
- 0.00