Nigeria's Invisible Solar Transition: Estimating Distributed Solar Capacity from Trade Data, 2017–2025, with Evidence through September 2026

Official statistics report 285 MW of solar capacity in Nigeria at the end of 2025 (IRENA, 2026), while Chinese customs-based records compiled by Ember indicate 4,959 MW of panel shipments to Nigeria between 2017 and 2025. These measures are not directly comparable: shipments may be re-exported, held in inventory, damaged or installed after a delay. This study therefore estimates Nigeria’s installed distributed solar stock using a monthly stock–flow model that explicitly allows for the domestic installation share, shipment-to-installation lag and system retirement. A 10,000-draw Monte Carlo analysis propagates uncertainty in these assumptions. The central stock–flow estimate is 2.824 GW at end-2025; the Monte Carlo median is 2.773 GW, with a 90% interval of 2.201–3.379 GW. The median is approximately 9.7 times the IRENA figure, implying that about 90% of the estimated stock is not represented in the official series. The estimate is conditional on assumptions about the share of Chinese shipments installed in Nigeria and the timing of installation; it is not a direct census of operating systems. To examine the economic context of the import expansion, the paper constructs a relative-price indicator measuring the watts of module capacity purchasable with one litre of diesel. Monthly regressions and an autoregressive distributed lag model indicate a positive association between this indicator and panel imports; the reported long-run elasticity is 0.61. The June 2023 subsidy-removal period is associated with a higher import level, although the unknown-break-date test does not establish a statistically significant structural break. The estimated 2025 solar stock could generate approximately 3.95 TWh annually at the assumed yield, equivalent to 10.1% of reported grid generation as a scale comparison, not a measured displacement rate. The findings suggest that Nigeria’s distributed solar market may be substantially undercounted and that customs, installer and survey data should be integrated into national energy statistics.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-25
DOI
https://doi.org/10.5281/zenodo.24549298
Primary Topic
Renewable Energy and Sustainability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Nigeria's Invisible Solar Transition: Estimating Distributed Solar Capacity from Trade Data, 2017–2025, with Evidence through September 2026

Emmanuel O. Ekhator
Zenodo (CERN European Organization for Nuclear Research)
Renewable Energy and Sustainability
article

Nigeria's Invisible Solar Transition: Estimating Distributed Solar Capacity from Trade Data, 2017–2025, with Evidence through September 2026

Emmanuel O. Ekhator
article en

Abstract

Official statistics report 285 MW of solar capacity in Nigeria at the end of 2025 (IRENA, 2026), while Chinese customs-based records compiled by Ember indicate 4,959 MW of panel shipments to Nigeria between 2017 and 2025. These measures are not directly comparable: shipments may be re-exported, held in inventory, damaged or installed after a delay. This study therefore estimates Nigeria’s installed distributed solar stock using a monthly stock–flow model that explicitly allows for the domestic installation share, shipment-to-installation lag and system retirement. A 10,000-draw Monte Carlo analysis propagates uncertainty in these assumptions. The central stock–flow estimate is 2.824 GW at end-2025; the Monte Carlo median is 2.773 GW, with a 90% interval of 2.201–3.379 GW. The median is approximately 9.7 times the IRENA figure, implying that about 90% of the estimated stock is not represented in the official series. The estimate is conditional on assumptions about the share of Chinese shipments installed in Nigeria and the timing of installation; it is not a direct census of operating systems. To examine the economic context of the import expansion, the paper constructs a relative-price indicator measuring the watts of module capacity purchasable with one litre of diesel. Monthly regressions and an autoregressive distributed lag model indicate a positive association between this indicator and panel imports; the reported long-run elasticity is 0.61. The June 2023 subsidy-removal period is associated with a higher import level, although the unknown-break-date test does not establish a statistically significant structural break. The estimated 2025 solar stock could generate approximately 3.95 TWh annually at the assumed yield, equivalent to 10.1% of reported grid generation as a scale comparison, not a measured displacement rate. The findings suggest that Nigeria’s distributed solar market may be substantially undercounted and that customs, installer and survey data should be integrated into national energy statistics.

Zenodo (CERN European Organization for Nuclear Research)
University of Port Harcourt (NG)
Renewable Energy and Sustainability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon