Frequency and Causes of Blood Component Discard in a Tertiary Care Hospital Blood Bank: A Five-Year Retrospective Study

Introduction Blood and its components play a crucial role in healthcare, making their use vital for transfusion services. Disposal of blood components presents clinical, ethical, and financial challenges. This study aimed to assess the component-wise discard rates and identify the reasons for blood component discard at a tertiary care hospital blood bank over a five-year period. Materials and methods A retrospective cross-sectional study was conducted at the Blood Bank, Department of Pathology, Government Medical College and Hospital, Nagpur, from January 2021 to December 2025. This study included 54,046 blood donors. Information on blood collection, component preparation, discarded units, and disposal reasons was extracted from blood bank records. The discard rate was calculated as the proportion of discarded units among total components prepared. Results Throughout the study period, 1,10,886 blood components were produced, of which 3,932 were discarded, leading to a discard rate of 3.5%. Platelet concentrates had the highest discard rate (851, 4.9%). Subsequently, fresh frozen plasma accounted for 1,432 (3.6%), while packed red blood cells made up 1,273 (3.2%), and whole blood constituted 376 (2.7%). The primary reason for discard was expiry (2,296, 58.39%), followed by TTI positivity (380, 9.66%), returned unused units (294, 7.48%), undercollection (268, 6.82%), leakage (264, 6.71%), hemolysis (220, 5.60%), and clotting (210, 5.34%). Among TTIs, the highest occurrence was of HBsAg positivity, followed by syphilis, HIV, and HCV, with no malaria-positive units identified. Conclusion The overall discard rate was within acceptable limits, although a substantial proportion of wastage, particularly due to expiry, was potentially preventable. Strengthening inventory management, adherence to standard operating procedures, and staff training may help minimise avoidable blood component wastage.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-11-25
DOI
https://doi.org/10.7759/cureus.120273
Primary Topic
Blood donation and transfusion practices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Frequency and Causes of Blood Component Discard in a Tertiary Care Hospital Blood Bank: A Five-Year Retrospective Study

Pratik Chide, Pradip Jadhav, Rashmi Wankhade, Kirti Jaiswal
Cureus
Blood donation and transfusion practices
article

Frequency and Causes of Blood Component Discard in a Tertiary Care Hospital Blood Bank: A Five-Year Retrospective Study

Pratik Chide, Pradip Jadhav, Rashmi Wankhade, Kirti Jaiswal
article en

Abstract

Introduction Blood and its components play a crucial role in healthcare, making their use vital for transfusion services. Disposal of blood components presents clinical, ethical, and financial challenges. This study aimed to assess the component-wise discard rates and identify the reasons for blood component discard at a tertiary care hospital blood bank over a five-year period. Materials and methods A retrospective cross-sectional study was conducted at the Blood Bank, Department of Pathology, Government Medical College and Hospital, Nagpur, from January 2021 to December 2025. This study included 54,046 blood donors. Information on blood collection, component preparation, discarded units, and disposal reasons was extracted from blood bank records. The discard rate was calculated as the proportion of discarded units among total components prepared. Results Throughout the study period, 1,10,886 blood components were produced, of which 3,932 were discarded, leading to a discard rate of 3.5%. Platelet concentrates had the highest discard rate (851, 4.9%). Subsequently, fresh frozen plasma accounted for 1,432 (3.6%), while packed red blood cells made up 1,273 (3.2%), and whole blood constituted 376 (2.7%). The primary reason for discard was expiry (2,296, 58.39%), followed by TTI positivity (380, 9.66%), returned unused units (294, 7.48%), undercollection (268, 6.82%), leakage (264, 6.71%), hemolysis (220, 5.60%), and clotting (210, 5.34%). Among TTIs, the highest occurrence was of HBsAg positivity, followed by syphilis, HIV, and HCV, with no malaria-positive units identified. Conclusion The overall discard rate was within acceptable limits, although a substantial proportion of wastage, particularly due to expiry, was potentially preventable. Strengthening inventory management, adherence to standard operating procedures, and staff training may help minimise avoidable blood component wastage.

Cureus
Government Medical College (IN), Datta Meghe Institute of Higher Education and Research (IN)
Blood donation and transfusion practices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon