Układ do badania uszkodzeń izolacji między blachami w rdzeniach stojanów maszyn indukcyjnych średnich mocy MASKAND 2
This paper presents the MASKAND 2 system for detecting interlaminar insulation faults in stator cores of medium-power induction machines. The method is based on excitation of a circumferential magnetic field and point-wise measurement using a dual Hall-sensor probe, enabling high spatial resolution and sensitivity. Unlike thermal and ELCID methods, the proposed system requires lower excitation power and allows direct calibration on the tested core, with results expressed in equivalent short-circuit current units.
Authors
- Michał Rad (ORCID: https://orcid.org/0000-0002-5052-8343)
Publication Details
- Journal
- PRZEGLĄD ELEKTROTECHNICZNY
- Published
- 2026-11-26
- DOI
- https://doi.org/10.15199/48.2026.11.7
- Primary Topic
- Non-Destructive Testing Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00