NV Quantum Sensors Track the Microenvironment of Living Cells at Super-Resolution

The researchers developed SMID, a technique that combines nitrogen-vacancy (NV) quantum sensing in fluorescent nanodiamonds with structured illumination microscopy (SIM). In test samples, SMID achieved a spatial resolution of 136 nm and a temporal resolution of 150 ms for T₁ sensing, while in living HeLa cells it achieved resolutions of 161 nm for optical imaging and 178 nm for T₁-based quantum sensing. Tracking NV sensors at multiple intracellular locations revealed spatially distinct ROS-related T₁ dynamics after chemical stimulation, including oscillatory behavior at some sites. [Quantum Biology Society] Temperature, reactive oxygen species (ROS), and ionic conditions are not uniform throughout a cell. Metabolism and signaling take place in distinct environments within compartments such as mitochondria, the nucleus, and the cytoplasm, and even the same stimulus can produce different local physicochemical responses at different intracellular locations. The challenge is measuring these changes inside a living cell with both high spatial and temporal resolution. Fluorescence-based sensors can be limited by photobleaching and phototoxicity, while electrochemical approaches can monitor dynamic activity but generally lack the spatial resolution needed to resolve fine intracellular environments. A research team led primarily by Zhejiang University, with participation from Zhejiang Normal University and China Jiliang University, addressed this problem by integrating quantum sensing with super-resolution microscopy. The authors are Yuxian Lu, Yibo Yang, Ke Xu, Zihan Mao, Lu Yin, Yang Xu, Zengrong Zhou, Xin Wang, Chi Zhang, Wenxin Zhu, and Jiandong Feng. In the study, released as an Article in Press in Nature Communications, the researchers used nitrogen-vacancy centers in fluorescent nanodiamonds (FNDs) as quantum sensors and combined them with structured illumination microscopy (SIM) and deconvolution. They named the resulting platform Super-resolution Multi-physical field Imaging with Deconvolution, or SMID. The manuscript was received on December 3, 2025, and accepted on September 22, 2026, with Jiandong Feng as the corresponding author. ■ Seeing Position with Light and Reading the Environment with NV Spins An NV center is an atomic-scale defect in diamond in which one carbon atom is replaced by nitrogen and an adjacent carbon site is vacant. The electronic spin associated with this defect can be manipulated and read out using light and microwaves, while responding sensitively to quantities such as magnetic noise and temperature in its surroundings. For biological experiments, fluorescent nanodiamonds containing NV centers can be introduced into cells and used as probes of local physicochemical conditions. One limitation of conventional intracellular NV sensing is that fluorescence signals from neighboring sensors can overlap. When several nanodiamonds lie closer together than the optical diffraction limit, they can appear as a single bright spot, making it difficult to determine which local environment produced a particular sensor response. SMID addresses this problem using structured illumination microscopy. The sample is sequentially illuminated with striped light patterns of different orientations and phases. Nine illumination patterns, combining three orientations with three phases, are used to reconstruct an image with spatial information beyond the conventional diffraction limit. The platform then combines this super-resolution localization with optically detected magnetic resonance (ODMR) and spin-lattice relaxation time, T₁, measurements of the NV centers. This allows the researchers to map not only where individual nanodiamonds are located, but also aspects of their surrounding temperature and radical-related environment. The researchers implemented three imaging modes. SMID-OPT provides super-resolved localization of the nanodiamond probes. SMID-TEMP measures temperature using shifts in the NV zero-field splitting detected by ODMR. SMID-T1 measures the spin-lattice relaxation time of NV centers, which is sensitive to nearby paramagnetic species and free-radical-related magnetic noise. Instead of obtaining a single averaged measurement over a whole cell or a broad region, SMID therefore links the position of multiple quantum sensors to the local physicochemical environment surrounding each one. ■ 136 nm in Test Samples and 161–178 nm in Living Cells The researchers first validated the optical performance of SMID using samples outside cells. Two fluorescent nanodiamonds separated by approximately 175 nm, as confirmed by scanning electron microscopy, appeared overlapped in conventional wide-field fluorescence images. SMID, however, resolved the two particles separately. Fourier ring correlation analysis gave a spatial resolution of 136 nm for SMID in these test samples. That 136 nm figure requires some qualification. It is a representative spatial resolution measured in the in vitro validation experiment; it does not mean that every form of quantum sensing performed inside living cells achieved 136 nm resolution. In living HeLa cells, Fourier ring correlation analysis yielded a resolution of 161 nm for the optical localization mode, SMID-OPT, and 178 nm for the T₁-based quantum sensing mode, SMID-T1. Both represented roughly a twofold resolution improvement over the diffraction limit of the researchers' conventional optical system. Temporal resolution also depends on the measurement mode. For SMID-T1, the researchers used a 50 ms exposure for each illumination pattern together with a rolling reconstruction procedure. Although nine illumination patterns contribute to super-resolution imaging, the rolling processing scheme allowed SMID-T1 measurements to reach a temporal resolution of 150 ms. For large-area imaging, the researchers instead combined 5 × 5 smaller fields of view to cover an area of 180 × 180 μm² in 12 seconds. This demonstrated that the system could examine not only highly localized intracellular microenvironments but also larger areas containing multiple cells while retaining super-resolution information. ■ ROS-Related Signals Behaved Differently at Different Locations Inside the Cell The researchers then internalized fluorescent nanodiamonds into living HeLa cells, separately labeled mitochondria, and compared T₁ signals from NV sensors located near mitochondria, in the cytoplasm, and in the nucleus. The T₁ relaxation time can be altered by surrounding paramagnetic ions and free radicals. In vitro calibration experiments using hydroxyl radicals showed that the measured T₁ values changed with radical concentration. In living cells, the researchers therefore used T₁ as an indicator of the relative ROS-related microenvironment. In static comparisons, mitochondrial regions showed shorter T₁ values, a trend the researchers interpreted as corresponding to relatively higher ROS levels and potentially reflecting metabolic activity in mitochondria. SMID-T1, however, does not selectively count a single ROS species. Multiple paramagnetic species and other aspects of the local physicochemical environment can influence the T₁ relaxation time inside a cell. The live-cell results are therefore better interpreted as differences in relative ROS-related microenvironments rather than as absolute concentrations of one specific reactive oxygen species. The researchers next perturbed the cells with superoxide dismutase (SOD), which reduces superoxide-related oxidative stress, followed by carbonyl cyanide 3-chlorophenylhydrazone (CCCP), which disrupts mitochondrial activity and was used in the study to promote apoptosis. In conventional wide-field T₁ measurements, the spatially averaged signal showed a relatively simple pattern: T₁ increased after SOD treatment and subsequently decreased after CCCP was introduced. When the researchers resolved individual nanodiamond sensors using SMID-T1, however, different sites within the same cell displayed substantially different responses. They classified these local responses into five characteristic types. The groups differed in the magnitude and direction of T₁ changes following SOD and CCCP treatment, as well as in the intracellular regions where the sensors were located. This showed that local microenvironmental heterogeneity can be obscured when only an average signal from the whole field is examined. One particularly notable pattern, designated Type 5, did not simply rise or fall after stimulation. Instead, the ROS-related T₁ signal oscillated repeatedly over time. The researchers suggest that these oscillations may reflect dynamic feedback within the cellular redox system, such as periodic activation of antioxidant defenses or rhythmic variations in mitochondrial activity. The specific biochemical mechanism responsible for the oscillations, however, was not directly established in this study. ■ Turning Intracellular Averages into Maps with Quantum Sensors The main advance of this work is not simply an increase in the sensitivity of the NV sensor itself. The important step is the ability to spatially separate multiple NV probes below the optical diffraction limit and associate each probe with information about its local microenvironment. Previous intracellular NV quantum-sensing studies had already used individual fluorescent nanodiamonds to examine quantities such as temperature and free-radical-related environments. SMID adds super-resolution structural imaging, allowing the locations, T₁ signals, and temperature information of multiple sensors to be spatially distinguished within the same living cell. Figure 4 of the paper demonstrates this multimodal capability by mapping optical position, T₁, and temperature in the same living cells. The researchers report 161 nm resolution for SMID-OPT and 178 nm for SMID-T1, and they image a 180 × 180 μm² field of view within 12 seconds. Figure 5 then shows how individual sensors distributed around mitochondria, the cytop

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-26
DOI
https://doi.org/10.5281/zenodo.24547243
Primary Topic
Diamond and Carbon-based Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

NV Quantum Sensors Track the Microenvironment of Living Cells at Super-Resolution

inquantio
Zenodo (CERN European Organization for Nuclear Research)
Diamond and Carbon-based Materials Research
article

NV Quantum Sensors Track the Microenvironment of Living Cells at Super-Resolution

inquantio
article en

Abstract

The researchers developed SMID, a technique that combines nitrogen-vacancy (NV) quantum sensing in fluorescent nanodiamonds with structured illumination microscopy (SIM). In test samples, SMID achieved a spatial resolution of 136 nm and a temporal resolution of 150 ms for T₁ sensing, while in living HeLa cells it achieved resolutions of 161 nm for optical imaging and 178 nm for T₁-based quantum sensing. Tracking NV sensors at multiple intracellular locations revealed spatially distinct ROS-related T₁ dynamics after chemical stimulation, including oscillatory behavior at some sites. [Quantum Biology Society] Temperature, reactive oxygen species (ROS), and ionic conditions are not uniform throughout a cell. Metabolism and signaling take place in distinct environments within compartments such as mitochondria, the nucleus, and the cytoplasm, and even the same stimulus can produce different local physicochemical responses at different intracellular locations. The challenge is measuring these changes inside a living cell with both high spatial and temporal resolution. Fluorescence-based sensors can be limited by photobleaching and phototoxicity, while electrochemical approaches can monitor dynamic activity but generally lack the spatial resolution needed to resolve fine intracellular environments. A research team led primarily by Zhejiang University, with participation from Zhejiang Normal University and China Jiliang University, addressed this problem by integrating quantum sensing with super-resolution microscopy. The authors are Yuxian Lu, Yibo Yang, Ke Xu, Zihan Mao, Lu Yin, Yang Xu, Zengrong Zhou, Xin Wang, Chi Zhang, Wenxin Zhu, and Jiandong Feng. In the study, released as an Article in Press in Nature Communications, the researchers used nitrogen-vacancy centers in fluorescent nanodiamonds (FNDs) as quantum sensors and combined them with structured illumination microscopy (SIM) and deconvolution. They named the resulting platform Super-resolution Multi-physical field Imaging with Deconvolution, or SMID. The manuscript was received on December 3, 2025, and accepted on September 22, 2026, with Jiandong Feng as the corresponding author. ■ Seeing Position with Light and Reading the Environment with NV Spins An NV center is an atomic-scale defect in diamond in which one carbon atom is replaced by nitrogen and an adjacent carbon site is vacant. The electronic spin associated with this defect can be manipulated and read out using light and microwaves, while responding sensitively to quantities such as magnetic noise and temperature in its surroundings. For biological experiments, fluorescent nanodiamonds containing NV centers can be introduced into cells and used as probes of local physicochemical conditions. One limitation of conventional intracellular NV sensing is that fluorescence signals from neighboring sensors can overlap. When several nanodiamonds lie closer together than the optical diffraction limit, they can appear as a single bright spot, making it difficult to determine which local environment produced a particular sensor response. SMID addresses this problem using structured illumination microscopy. The sample is sequentially illuminated with striped light patterns of different orientations and phases. Nine illumination patterns, combining three orientations with three phases, are used to reconstruct an image with spatial information beyond the conventional diffraction limit. The platform then combines this super-resolution localization with optically detected magnetic resonance (ODMR) and spin-lattice relaxation time, T₁, measurements of the NV centers. This allows the researchers to map not only where individual nanodiamonds are located, but also aspects of their surrounding temperature and radical-related environment. The researchers implemented three imaging modes. SMID-OPT provides super-resolved localization of the nanodiamond probes. SMID-TEMP measures temperature using shifts in the NV zero-field splitting detected by ODMR. SMID-T1 measures the spin-lattice relaxation time of NV centers, which is sensitive to nearby paramagnetic species and free-radical-related magnetic noise. Instead of obtaining a single averaged measurement over a whole cell or a broad region, SMID therefore links the position of multiple quantum sensors to the local physicochemical environment surrounding each one. ■ 136 nm in Test Samples and 161–178 nm in Living Cells The researchers first validated the optical performance of SMID using samples outside cells. Two fluorescent nanodiamonds separated by approximately 175 nm, as confirmed by scanning electron microscopy, appeared overlapped in conventional wide-field fluorescence images. SMID, however, resolved the two particles separately. Fourier ring correlation analysis gave a spatial resolution of 136 nm for SMID in these test samples. That 136 nm figure requires some qualification. It is a representative spatial resolution measured in the in vitro validation experiment; it does not mean that every form of quantum sensing performed inside living cells achieved 136 nm resolution. In living HeLa cells, Fourier ring correlation analysis yielded a resolution of 161 nm for the optical localization mode, SMID-OPT, and 178 nm for the T₁-based quantum sensing mode, SMID-T1. Both represented roughly a twofold resolution improvement over the diffraction limit of the researchers' conventional optical system. Temporal resolution also depends on the measurement mode. For SMID-T1, the researchers used a 50 ms exposure for each illumination pattern together with a rolling reconstruction procedure. Although nine illumination patterns contribute to super-resolution imaging, the rolling processing scheme allowed SMID-T1 measurements to reach a temporal resolution of 150 ms. For large-area imaging, the researchers instead combined 5 × 5 smaller fields of view to cover an area of 180 × 180 μm² in 12 seconds. This demonstrated that the system could examine not only highly localized intracellular microenvironments but also larger areas containing multiple cells while retaining super-resolution information. ■ ROS-Related Signals Behaved Differently at Different Locations Inside the Cell The researchers then internalized fluorescent nanodiamonds into living HeLa cells, separately labeled mitochondria, and compared T₁ signals from NV sensors located near mitochondria, in the cytoplasm, and in the nucleus. The T₁ relaxation time can be altered by surrounding paramagnetic ions and free radicals. In vitro calibration experiments using hydroxyl radicals showed that the measured T₁ values changed with radical concentration. In living cells, the researchers therefore used T₁ as an indicator of the relative ROS-related microenvironment. In static comparisons, mitochondrial regions showed shorter T₁ values, a trend the researchers interpreted as corresponding to relatively higher ROS levels and potentially reflecting metabolic activity in mitochondria. SMID-T1, however, does not selectively count a single ROS species. Multiple paramagnetic species and other aspects of the local physicochemical environment can influence the T₁ relaxation time inside a cell. The live-cell results are therefore better interpreted as differences in relative ROS-related microenvironments rather than as absolute concentrations of one specific reactive oxygen species. The researchers next perturbed the cells with superoxide dismutase (SOD), which reduces superoxide-related oxidative stress, followed by carbonyl cyanide 3-chlorophenylhydrazone (CCCP), which disrupts mitochondrial activity and was used in the study to promote apoptosis. In conventional wide-field T₁ measurements, the spatially averaged signal showed a relatively simple pattern: T₁ increased after SOD treatment and subsequently decreased after CCCP was introduced. When the researchers resolved individual nanodiamond sensors using SMID-T1, however, different sites within the same cell displayed substantially different responses. They classified these local responses into five characteristic types. The groups differed in the magnitude and direction of T₁ changes following SOD and CCCP treatment, as well as in the intracellular regions where the sensors were located. This showed that local microenvironmental heterogeneity can be obscured when only an average signal from the whole field is examined. One particularly notable pattern, designated Type 5, did not simply rise or fall after stimulation. Instead, the ROS-related T₁ signal oscillated repeatedly over time. The researchers suggest that these oscillations may reflect dynamic feedback within the cellular redox system, such as periodic activation of antioxidant defenses or rhythmic variations in mitochondrial activity. The specific biochemical mechanism responsible for the oscillations, however, was not directly established in this study. ■ Turning Intracellular Averages into Maps with Quantum Sensors The main advance of this work is not simply an increase in the sensitivity of the NV sensor itself. The important step is the ability to spatially separate multiple NV probes below the optical diffraction limit and associate each probe with information about its local microenvironment. Previous intracellular NV quantum-sensing studies had already used individual fluorescent nanodiamonds to examine quantities such as temperature and free-radical-related environments. SMID adds super-resolution structural imaging, allowing the locations, T₁ signals, and temperature information of multiple sensors to be spatially distinguished within the same living cell. Figure 4 of the paper demonstrates this multimodal capability by mapping optical position, T₁, and temperature in the same living cells. The researchers report 161 nm resolution for SMID-OPT and 178 nm for SMID-T1, and they image a 180 × 180 μm² field of view within 12 seconds. Figure 5 then shows how individual sensors distributed around mitochondria, the cytop

Zenodo (CERN European Organization for Nuclear Research)
Diamond and Carbon-based Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon