Architecture evaluation and screening of a liquid hydrogen cold energy and low-grade heat recovery system for marine liquid hydrogen fuel utilisation

Architecture selection for the combined recovery of liquid hydrogen cold energy and low-grade engine waste heat in marine applications requires balancing power generation, economic cost, and system integration burden. This study adopts a baseline comprising a direct expansion branch and a closed recuperative supercritical hydrogen Brayton cycle. Connection rules for one or two organic Rankine cycles in series along the fuel stream, with optional parallel augmentation, generate four additional configurations. A system integration burden index is proposed to combine equipment mass, volume, and structural complexity. Process simulation and a genetic algorithm are used for three-objective optimisation of net power output, total annualised cost, and integration burden. The results show that cycle connections directly affect power distribution. At the compromise operating points, increased organic Rankine cycle output in the configurations with parallel augmentation is offset by reduced output from the other cycles, yielding no system net power gain. The configuration with one organic Rankine cycle in series is selected as the preferred option. It produces 375.78 kW, 17.98% above the baseline, achieves a net present value of $2.546 million, and has the lowest total annualised cost and integration burden among the configurations incorporating organic Rankine cycles. Two cycles in series increase the maximum net power output to 700.80 kW, only 1.48% above the corresponding maximum for one cycle. Structural complexity dominates differences in integration burden. At fixed compromise operating points, the burden ranking remains unchanged under five weighting schemes and simultaneous ± 5 % changes in the mass and volume scaling coefficients.

Authors

Institutions

Publication Details

Journal
Applied Thermal Engineering
Published
2026-11-26
DOI
https://doi.org/10.1016/j.applthermaleng.2026.134141
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Architecture evaluation and screening of a liquid hydrogen cold energy and low-grade heat recovery system for marine liquid hydrogen fuel utilisation

Peilin Zhou, Binteng Gu, Haibin Wang, Lin Yang (45852) et al.
Applied Thermal Engineering
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Architecture evaluation and screening of a liquid hydrogen cold energy and low-grade heat recovery system for marine liquid hydrogen fuel utilisation

Peilin Zhou, Binteng Gu, Haibin Wang, Lin Yang (45852), Yinhua Liu
article en

Abstract

Architecture selection for the combined recovery of liquid hydrogen cold energy and low-grade engine waste heat in marine applications requires balancing power generation, economic cost, and system integration burden. This study adopts a baseline comprising a direct expansion branch and a closed recuperative supercritical hydrogen Brayton cycle. Connection rules for one or two organic Rankine cycles in series along the fuel stream, with optional parallel augmentation, generate four additional configurations. A system integration burden index is proposed to combine equipment mass, volume, and structural complexity. Process simulation and a genetic algorithm are used for three-objective optimisation of net power output, total annualised cost, and integration burden. The results show that cycle connections directly affect power distribution. At the compromise operating points, increased organic Rankine cycle output in the configurations with parallel augmentation is offset by reduced output from the other cycles, yielding no system net power gain. The configuration with one organic Rankine cycle in series is selected as the preferred option. It produces 375.78 kW, 17.98% above the baseline, achieves a net present value of $2.546 million, and has the lowest total annualised cost and integration burden among the configurations incorporating organic Rankine cycles. Two cycles in series increase the maximum net power output to 700.80 kW, only 1.48% above the corresponding maximum for one cycle. Structural complexity dominates differences in integration burden. At fixed compromise operating points, the burden ranking remains unchanged under five weighting schemes and simultaneous ± 5 % changes in the mass and volume scaling coefficients.

Applied Thermal EngineeringVol. 311
Harbin Engineering University (CN), University of Strathclyde (GB)
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.